REVEX
2PH from 120A to 210A
User’s manual
Technical Specifications
6.1 General features
Cover and Socket material:
PolymericV2
Utilization Category:
AC-51 AC-55b
IP Code:
20
Method of Connecting:
Load in Delta, Load in Star
Auxiliary voltage
Order Code RX2___-_4:
24Vdc (1A)
Relay output for Heater Break Alarm
0.5A a 125VAC
(only with HB option)
6.2 Input features
Digital Input:
4 ÷ 30Vdc 5mA Max (ON >4Vdc OFF<1Vdc) 5Hz max
Volt Analogic input:
0 ÷ 10Vdc impedance 15 kΩ
Current Analogic input:
4 ÷ 20mA impedance 100 Ω
Potentiometer:
10 kΩ min.
Logic input SSR (Fast Enable):
4 ÷ 30Vdc 5mA Max (ON >4Vdc OFF <1Vdc)
3HZ Max duty cycle min. 100 ms
6.3 Output features (power device)
Current
Nominal
Voltage
range (Ue)
Repetitive peak
reverse voltage
(Uimp)
Latching
current
Max peak
one cycle
Leakage
current
FUSE I2T
value
Suggested
A2s
(at500V)
Frequency
range
Power loss
Thy
Fuse
Isolation
Voltage
(Ui)
(A)
(V)
(480V)
(600V)
(mAeff)
(10 msec.)
(A)
(mAeff)
tp=
10msec
(Hz)
I =Inom (W)
(Vac)
120
24÷600
1200
1600
600
1900
15
14280
47÷70
398
3000
150
24÷600
1200
1600
300
5000
15
17500
47÷70
409
3000
180
24÷600
1200
1600
300
5000
15
30800
47÷70
486
3000
210
24÷600
1200
1600
300
5000
15
53900
47÷70
598
3000
6.4 Environmental installation conditions
Ambient temperature
0-40°C (32-104°F) at nominal current. Over 40°C-104°F use
the derating curve (max 50°C).
Storage temperature
-25°C to 70°C -13°F to 158°F
Installation place
Don’t install at direct sun light, where there are conductive
dust, corrosive gas, vibration or water and also in salty
environmental.
Altitude
Up to 1000 meter over sea level. For higher altitude reduce
the nominal current of 2% for each 100m over 1000m
Humidity
From 5 to 95% without condense and ice
Pollution Level
Up to 2nd Level ref. IEC 60947-1 6.1.3.2