5
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE
Mains Electricity Connection
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED
WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE.
Warning! This appliance must be earthed
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who
will comply with the I.E.E. and local regulations.
The wires in the mains lead of this appliance are coloured in accordance with the following code:
Green
&
Yellow = Earth, Blue = Neutral, Brown = Live.
As the colours of the wires in the mains lead for the appliance may not correspond
with the coloured markings identifying the terminals connecting to the fuse spur,
proceed as follows:
•
The wire which is coloured green and yellow must be connected to the
terminal marked E (Earth) or coloured green.
•
The wire which is coloured blue must be connected to the terminal marked
N (Neutral), or coloured black.
•
The wire which is coloured brown must be connected to the terminal marked
L (Live), or coloured red.
Note: Use a 3A Fuse
Assembly and electrical connection should be carried out by specialised personnel.
When installing this product we recommend you seek the help of another individual.
Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the
extractor from the mains electrical supply after installation.
This appliance is intended to be connected to the mains electrical supply by means of an isolation switch and fused
spur and is intended to be protected by a 3A fuse. The use of a 13A fuse can cause damage to the internal wiring in the
event of a fault, and may also invalidate the warranty.
Electrical Information
Mains electrical voltage: 230 – 240Vac, 50Hz
Total rated power consumption:
238W
Troubleshooting
If your extractor is not working:
1. Check that the mains supply has not been switched off.
2. Check that the fuse in the spur has not blown.