17
the adjustment screw to secure the
extractor firmly in position
Note:
When fixing to an 18mm MDF false
ceiling, four 2mm spacers have been
provided to make the mounts 20mm
thick (minimum).
If the extractor needs to be removed
after installation for any reason, the
fixing clips should be slackened and
then can be accessed by removing
the foil covering. Push them to fold
them into line with the body. Take care
and get assistance when doing this to
prevent the risk of injury caused by the
extractor falling from the ceiling.
6. Re-connect the light terminals
and light panels to complete the
installation. If the decorative cover
panel was removed then refit this
also.
fig. 16
False ceiling (MDF)
18 m
m
Spacer
fig. 17
2mm