18
Mains electricity connection
THIS APPLIANCE COMES FITTED WITH A 3 PIN PLUG,
CONTAINING A 3A FUSE, BUT CAN BE CONNECTED TO THE
MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED
WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET
AND PROTECTED BY A 3A FUSE.
If hard-wiring, we recommend that the
appliance is connected by a qualified
electrician, who is a member of the
N.I.C.E.I.C. and who will comply with the
I.E.E. and local regulations.
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
BLUE = NEUTRAL, BROWN = LIVE, GREEN+YELLOW = EARTH
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
connecting to the fused spur, proceed as follows:
•
The wire which is coloured blue must be connected to the terminal
marked N (Neutral), or coloured black.
•
The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured red.
•
The wire coloured green and yellow must be connected to the
terminal marked E (Earth) or coloured green or green and yellow.
DOUBLE POLE
SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE
Fig. 13