Installation and Troubleshooting Guide
NOTE: This installation is to be completed by an Authorized Dealer or Professional Service
Technician. For questions regarding installation or warranty, call CDI Tech Support
at 866-423-4832. Do not return to the Dealer or Distributor where the part was purchased.
Contact CDI Electronics Directly for Return Materiel Authorization.
CDI Electronics, LLC
353 James Record Road SW
Huntsville, AL 35824 USA
Web Support: www.
cdielectronics.com
Tech Support: 1-866-423-4832
Order Parts: 1-800-467-3371
All rights reserved. Reproduction or use of content, in any manner, without express written permission by CDI Electronics, LLC., is prohibited.
Rev D
10/4/2018 Page - 2 of 2 QF-358
Maximum Output Test
(Verify the maximum output of your engine using the factory Service Manual)
1. Install a clamp on ammeter capable of reading at least 30 amperes in-line on the Red wire connected to the starter solenoid.
2. Connect a load bank to the battery.
3. In the water or on a Dynometer, start the engine and bring the RPM up to approximately 3500 in gear.
4. Turn on the load bank switches to increase the battery load to equal at least 20 Amps.
5. Check the ammeter, you should see approximately 16 Amps. If the amperage is too low, replace the battery and retest. If is still too
low, check the stator resistance and DVA.
6. Increase RPM to 5500 RPM in gear.
7. Turn on the load bank switches to increase the battery load to equal at least 30 Amps.
8. Check the ammeter, you should see approximately 20 Amps. If the
Bench Test (Disconnected)
Rectifier/Regulator Diode plate check:
1. Test the forward diodes between the three Green wires and the red wire, with the meter set to Diode test.
Meter Lead Read From
Meter Lead
Read To
Reading
Red
Green 1
Black
Red
about 0.5
Red
Green 2
Black
Red
about 0.5
Red
Green 3
Black
Red
about 0.5
Black
Green 1
Red
Red
Very high or open
Black
Green 2
Red
Red
Very high or open
Black
Green 3
Red
Red
Very high or open
2. Test for shorts to the Black ground wire, with the meter set to ohms test.
Meter Lead Read From
Meter Lead
Read To
Reading
Red
Green 1
Black
Black
Open or Reading in the M (Million) range.
Red
Green 2
Black
Black
Open or Reading in the M (Million) range.
Red
Green 3
Black
Black
Open or Reading in the M (Million) range.
Black
Green 1
Red
Black
Open or Reading in the M (Million) range.
Black
Green 2
Red
Black
Open or Reading in the M (Million) range.
Black
Green 3
Red
Black
Open or Reading in the M (Million) range.
Red
Red
Black
Black
Open or Reading in the M (Million) range.
Black
Red
Red
Black
Open or Reading in the M (Million) range.