Installation and Troubleshooting Guide 

 

 

 

    

NOTE: This installation is to be completed by an Authorized Dealer or Professional Service 

  Technician.  For questions regarding installation or warranty, call CDI Tech Support  
  at 866-423-4832. Do not return to the Dealer or Distributor where the part was purchased. 
  Contact CDI Electronics Directly for Return Materiel Authorization. 

CDI Electronics, LLC  

 353 James Record Road SW 

 Huntsville, AL 35824 USA 

Web Support: www.

cdielectronics.com

  

 Tech Support: 1-866-423-4832 

 Order Parts: 1-800-467-3371 

All rights reserved. Reproduction or use of content, in any manner, without express written permission by CDI Electronics, LLC., is prohibited. 

 

Rev D 

 10/4/2018                                                                     Page - 2 of 2                                                                                 QF-358 

 
 
 

 
 

Maximum Output Test  

(Verify the maximum output of your engine using the factory Service Manual) 

 
 

1.  Install a clamp on ammeter capable of reading at least 30 amperes in-line on the Red wire connected to the starter solenoid. 
2.  Connect a load bank to the battery. 
3.  In the water or on a Dynometer, start the engine and bring the RPM up to approximately 3500 in gear. 
4.  Turn on the load bank switches to increase the battery load to equal at least 20 Amps. 
5.  Check the ammeter, you should see approximately 16 Amps. If the amperage is too low, replace the battery and retest. If is still too 

low, check the stator resistance and DVA. 

6.  Increase RPM to 5500 RPM in gear. 
7.  Turn on the load bank switches to increase the battery load to equal at least 30 Amps. 
8.  Check the ammeter, you should see approximately 20 Amps. If the  

 

Bench Test (Disconnected) 

Rectifier/Regulator Diode plate check:  
1.  Test the forward diodes between the three Green wires and the red wire, with the meter set to Diode test.

 

 

Meter Lead  Read From  

Meter Lead  

Read To  

Reading  

 

 

Red  

Green 1 

Black   

Red  

 

about 0.5 

Red  

Green 2 

Black   

Red  

 

about 0.5  

Red  

Green 3 

Black   

Red  

 

about 0.5 

Black 

Green 1

 

Red 

 

Red 

 

Very high or open 

Black 

Green 2

 

Red 

 

Red  

 

Very high or open

 

Black 

Green 3

 

Red 

 

Red 

 

Very high or open

 

 

2.  Test for shorts to the Black ground wire, with the meter set to ohms test.

 

 

Meter Lead  Read From  

Meter Lead  

Read To  

Reading  

 

 

 

 

Red  

Green 1 

Black   

Black   

Open or Reading in the M (Million) range. 

Red  

Green 2 

Black   

Black   

Open or Reading in the M (Million) range. 

Red  

Green 3 

Black   

Black   

Open or Reading in the M (Million) range. 

Black 

Green 1

 

Red 

 

Black   

Open or Reading in the M (Million) range. 

Black 

Green 2

 

Red 

 

Black   

Open or Reading in the M (Million) range. 

Black 

Green 3

 

Red 

 

Black   

Open or Reading in the M (Million) range. 

Red  

Red 

 

Black   

Black   

Open or Reading in the M (Million) range. 

Black 

Red 

 

Red 

 

Black 

 

Open or Reading in the M (Million) range. 

 
 

 
  

 