background image

 

 

 

 

PROCEDURES TO START THE CONCENTRATOR "LA FENDEUSE" IN THE BEGINNING OF THE SEASON 

 

1.

 

Photo A – Install the "U-cup" at one end of the membrane, groove upward. 

2.

 

Photo B – Place the plug in the end of the membrane on the same side as the "U-cup". 

3.

 

Photo C – Put the stainless steel plate on the "U-cup" using a small flat screwdriver. 

4.

 

Photo G – Remove the cover from the post and make sure that the 4 Allen screws are unscrewed as 
much as possible. 

5.

 

Photo D – Place the membrane gently with the plate downward, raise the post and make sure it is well 
in place on the pump, either by turning the membrane or by gently shaking the post. 

6.

 

Photo E – Put the lid on. Tighten the large bolts. Make sure that the seals are greased. 

7.

 

Photo G – Using an Allen wrench, tighten the 4 small screws alternately one in front of the other until 
the 4 are screwed in. Do not over tighten. 

8.

 

Connect the hoses to the post (3 hoses). 

9.

 

Place a pre-filter cartridge in the blue bowl and close the 3 drains (turbine, pump and bottom of the 
post). 

10.

 

Start the pump (green button) to fill the entire system with water, open the valve on the top of the post 
to vent the air from the system. When the water exits through this valve, close it, stop everything, plug 
the post's electrical wire and restart the device. 

11.

 

You are now ready to start. Follow the instructions on the panel. 

12.

 

When the system is filled with water, if it is the first time you use the osmosis in the season, you must 
remove the preservative liquid or the contaminated water from the membrane. Concentrate enough 
sap  to  get  about  300  gallons  of  permeate  per  post.  Discard  the  concentrate  obtained  during  this 
operation.  As  soon  as the  desired  quantity  is  reached, perform  a  complete  wash  cycle  to thoroughly 
clean the membrane. When the wash cycle is complete, you will be ready to concentrate. Never leave a 
membrane that contains a preservative inside the post. 

For an effective wash of the Filmtec Mark-1 or H20 CDL MAX membrane, the pH of the water must be 
11 or 12. The pH increases by adding soap for this purpose.

 

NEVER  CONCENTRATE  ORDINARY  WATER  IN  ORDER  TO  OBTAIN  PERMEATE.  THE  HIGH  PRESSURE 
PUMP WILL BE DAMAGED BECAUSE IT WILL NOT BE CAPABLE OF BUILDING PRESSURE. IF THE MACHINE 
CONCENTRATES ORDINARY WATER, THE WARRANTY WILL BE VOID. 

Important: 

When the membrane is new, it is important to immerse it in water for 24 hours. 

 
 
 
 
 
 

Reviews: