background image

Perfect For

• 

Thin cuts of meat, fish or poultry

Easy To Use

• 

3-6 second response

• 

Backlit in blue

• 

Extra big digit

• 

Temperature guide

Features

• 

NSF

®

 Certified

• 

1.5 mm thin tip

• 

4.25"/10.8 cm stainless steel probe

• 

Water resistant

• 

Shatterproof

• 

Maximum & minimum

• 

Food-safe ABS plastic with BioCote

®

• 

Field calibration

• 

On/off button

• 

Auto-off after 10 minutes

• 

Mounting: loop

• 

Batteries & instructions included

Note:

 Remove sticker from display before use.

Get Professional Results  

Every Time!

Perfect for thin cuts of meat, fish or poultry. Simply 

flip down the rapid-response thermocouple probe 

and insert it into food as thin as 1/8-inch. BioCote

®

 

technology gives the water resistant housing 

constant, built-in antimicrobial protection, providing 

a finish that helps prevent microbes from growing on  

the surface. The display features extra big digits and 

can be backlit for low light conditions.
The TCT572 offers Minimum and Maximum modes. 

Minimum mode displays the lowest temperature 

among multiple readings. Maximum mode displays 

the highest temperature among multiple readings. 

Note:

 In the following instructions, names of the control 

buttons are shown in CAPS. Function information that appears 

on the display is shown in 

BOLD CAPS

.

Battery Installation

Power off the unit before installing the battery.  

A malfunction may occur if the power is on when  

the battery is installed. If a malfunction occurs, press 

the RESET button on the back or restart the device.
1. Using a small Phillips screwdriver, remove the 

screw on the top by turning it counter clockwise.

2. Pull side panel completely out.
3. Install two CR2032 batteries observing polarity 

shown in compartment.

4. Replace the battery cover.  

Important:

 The water resistant feature requires 

maintaining the rubber gasket evenly within the 

groove.

5. Fasten the screw on the top by turning it 

clockwise, being careful not to over-turn.

Model: TCT572

ProAccurate

®

 Folding  

Thermocouple Thermometer

 

-58 to +572°F/-50 to +300°C

Summary of Contents for ProAccurate TCT572

Page 1: ...ons The TCT572 offers Minimum and Maximum modes Minimum mode displays the lowest temperature among multiple readings Maximum mode displays the highest temperature among multiple readings Note In the following instructions names of the control buttons are shown in CAPS Function information that appears on the display is shown in BOLD CAPS Battery Installation Power off the unit before installing th...

Page 2: ...ay along with the last highest maximum temperature 2 To clear the MAX MIN reading Press the MAX MIN button once then press the CLEAR button appears on the display F Minimum Mode 1 Press the MAX MIN button twice MIN appears on the display along with the last lowest minimum temperature 2 To clear the MAX MIN reading Press the MAX MIN button twice then press the CLEAR button appears on the display G ...

Page 3: ...nd which may scratch the plastic and corrode the electronic circuits Do not subject the unit to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and distorted parts Do not tamper with the unit s internal components Doing so will invalidate the warranty on the unit and may cause unnecessary battery damage and distorted p...

Page 4: ...cteria that may affect this product According to EPA guidelines we cannot claim that the antimicrobial properties in this product protect users or others against bacteria viruses germs or other disease organisms This product does not protect users or others against food borne bacteria Always clean and wash this product thoroughly before and after each use USDA SAFE FOOD TEMPERATURES Beef Veal Lamb...

Reviews: