KCIN
Illuminated weatherproof Keypad with Remote Electronics 1, 2 or 3 relays
INSTALLATION MANUAL
5] WIRING DIAGRAM : KCIN 1-RELAY OUTPUT
D - 693 : Remote electronics
P3 jumper allows to the
user to modify its own
Pin code. To enable this
feature put the jumper
on. (see Programming
section in the instruction
manual)
P2 jumper resets the key-
pad to factory default
values. Remove the power
from the keypad then put
the jumper.
(see Programming section
in the instruction manual)
Power supply
12 to 24VAC
or 12 to 48VDC
H (Open) KCIN
Keypad mode
H (Closed) KCIN
Request-to-Enter
mode
Power supply
According to lock
specifi cations
White
Brown
Green or blue
Varistor
Relay
1
P2
P3
Request-to-Exit inputs
P1 request-to-exit input activates relay 1.
P2 request-to-exit input activates relay 2.
Latch or toggled output.
H input can be used with
a timer to enable free access
by pressing on any digit key
on the keypad.
When the contact is open
then the request-to-enter is disabled.
When the contact is closed then press
any key on the keypad to enter.
Outputs
Description
V
Input voltage 12V to 24V ac or 12V to 48V dc
V
Input voltage 12V to 24V ac or 12V to 48V dc
R1
N/C contact relay 1
C1
Common relay 1
T1
N/O contact relay 1
P1
Request-to-exit input relay 1
M
Common of input
H
Timer Contact
+
White wire keypad
-
Brown wire keypad
E
Green or Blue wire (illumination)
5
cdvi.com
cdvigroup.com
Fail safe lock
Fail secure lock