6] PROGRAMMING
GALEOR FACTORY SETTINGS:
- No user codes.
- Buzzer ON
- Time-out backlit:
3 Sec.
- Transmission time-out:
25 seconds
- Factory master code:
1 2 3 4 5.
- Programming time-out:
10 seconds.
- Channel choices:
Channel 1 = A,
Channel 2 = B.
AUDIBLE FEEDBACKS:
1 beep: Power-up (battery insertion)
1 long beep:
- Enter on menu,
- Validation of a programming choice,
- Exit from a menu choice.
2 beeps: Confirm enter in factory recovery
3 beeps: confirm factory recovery “A+1”
4 beeps:
- Confirm factory recovery “B+3”,
- Error for wrong channel,
- Error for insertion of a code already
Memorized.
USING RULES AND USER CODES:
- All the buttons can be used to
compose the personal access code,
except A and B.
- The master code must be composed
by 5 digits.
- The user codes can be composed by
4 or 5 digits according to initial setting
- The master code cannot be used as
transmission code.
EN
10
cdvigroup.com
1 beep
Error message if the
Master code typed
corresponds to User
code in memory
1 beep = OK
(4 beeps = Error)
Type the 5 digits of
the new Master code
A0
Change
Master code
1 beep
Error message if the User
code typed corresponds to
a user code in memory
-------- or --------
the memory is full
-------- or --------
is 12345
1 beep = OK
(4 beeps = Error)
Then press :
-“A” = Only channel 1
-”B” = Only channel 2
-”A & B” = Channel 1
or Channel 2
A1
User code
programming
Type the digits
of the USER CODE
Press “0” to confirm
The keypad comes without any setting for the user digit
number. At the battery insertion the 12 leds start to
blink, waiting for this setting.
PRESS the
key 4
for
4 sec
. to set 4-digits
user codes
--> 4 beeps
PRESS the
key 5
for
5 sec
. to set 5-digits
user codes
--> 5 beeps
After this setting, the keypad will accept only user codes
composed by 4 or 5 digits, according to the choice made.
If no change is done (change of the master code, user
code memorization, etc) just by removing the battery
the keypad comes back the factory settings and requires
again to set the number of digits.
Once set the number of digits and made any
change, the data-base remains definite and cannot
be changed unless a factory default procedure is
carried out (see procedure “B+3”).
7] GETTING STARTED