background image

PROMI500

PIN Code and/or Badge

STAND-ALONE PROXIMITY SYSTEM

WI

R

IN

G

  

D

IA

G

R

A

A

N

D

 I

N

S

T

R

U

C

T

IO

N

S

3

2

V

1

E

M B

O

C

T

5

12

RL1

RL2

3
2
1

ST1

ST2

1

3

I1

PB1

V1

Input voltage

12V ~ or =

230V~

strike

12 V 1 4 5 3 2

Wiring diagram

PCB front view

This device comes with a varistor.

The varistor must be connected on the strike terminal

(electromagnet…) operated by the device.

If this product operates more than one strikes, each of them
should have a varistor.
The varistor controls the overload produced by the strike coil

back emf.

B

Request-to-exit PB1

E

Alarm Input

M

Common PB1, E and 4

O

Relay 1 contact

C

Common

T

Relay 2 N/O contact

I1

Anti-tamper switch

V1

Varistor

ST1
ST2

Jumper for reset
Jumper for relay 1

RL1

Door relay

RL2

Alarm relay

12

Power supply

V

Power supply

1

Data

2

Buzzer

3

Green LED

4

Common M

5

Red LED

Auxiliary reader

(terminal connections)

Warning
Do not use a
switching
power supply
because of the
interference
radiation that
may disturb
the reading of
the badges

N/C contact RL1 (magnet)

N/O contact RL1 (strike)

See wiring diagram auxiliary reader

ST2

1

3

1

3

If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a

separate power supply than the one connected to the PROMI500.

Summary of Contents for PROMI500

Page 1: ...back emf B Request to exit PB1 E Alarm Input M Common PB1 E and 4 O Relay 1 contact C Common T Relay 2 N O contact I1 Anti tamper switch V1 Varistor ST1 ST2 Jumper for reset Jumper for relay 1 RL1 Do...

Page 2: ...rm Off Audible Signals 1 beep long Validation of data in programming mode master code proximity badge or time delay Or access code validated 2 beeps short Accessing the programming mode or exiting fro...

Page 3: ...hen the time delay in seconds 01 equal 1 second up to 99 for 99 seconds 00 sets a latched output toggle on toggle off The LED goes out for 1 second and an audible beep indicates the time delay has bee...

Page 4: ...ong beep will sound to confirm that the badge and PIN code have been stored To exit from the programming mode at any time press the key 2 beeps confirm that you have returned to the standby mode Reset...

Page 5: ...tays open the open contact will trigger the alarm relay according to the door relay output Momentary output the alarm time delay begins at the end of the door time delay If the door is maintained open...

Page 6: ...me User number Name Time delays Function n Values Programmed values Keypad key in delay 0 10 10 sec 99 99 sec Door open delay 1 01 1 sec 99 99 sec opened door before alarm 2 00 without alarm 01 10 sec...

Page 7: ...V 1 4 5 12 Distance minimum 60cm maximum 50 m Auxiliary reader terminal connections Input voltage 12V or 230V 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED PR...

Page 8: ...8 Template PROMI500 20 5 mm 105 mm 120 mm 135 mm 23 mm 43 mm 15 mm 38 mm 61 mm 75 5 mm Wiring access area 30 mm x 40 mm...

Page 9: ...9 Template DGLP or DGLI Auxiliary reader Block terminal 43x15 mm 60 mm 96 mm 75 mm 25 mm 6 mm...

Reviews: