Technical features

Input voltage

12 VAC/DC

Output

2 relays, N/O & N/C contact 3A /125V

Anti-triggering contact

500 mA 50 V ~ or  =

Badge entry

500 programmable badges

PIN Code

500 programmable codes, 5-digit PIN code

Master code

5-digit programmable code

Input

1 request-to-exit

Keyboard

12-digit keypad with built-in buzzer (audible signal)

Distance between the
second reader and the
PROMI500 unit

minimum 24 inches (60 cm)
maximum 45 yards (50 meters)
(cable minimum 7 x 0.6 mm

2

)

Default values

Master code:

12345

Relay time delay:

1 second

Key-in keypad:

10 seconds

Alarm:

Off

Audible Signals

1 beep (long) Validation of data in programming mode: master code,

proximity badge or time delay.
Or access code validated

2 beeps (short) Accessing the programming mode

or exiting from the programming mode

4 beeps (short) incorrect mode, user number time delays entered

Visual Signals

LED color

Normal mode

Programming mode

Green

Door relay activated

Code/Badge position empty

Red

Alarm relay activated

Code/Badge position busy

Orange

Programming mode

Orange flashing

Stand-by

Data computing error

Request-to-exit

The request-to-exit push button PB1 operates relay RL1.
The LED turns green when the relay is activated.

Warning: Do not use a switching power supply because of radiation
interference, which may disturb the reading of the badges.
.

Summary of Contents for PROMI500

Page 1: ...back emf B Request to exit PB1 E Alarm Input M Common PB1 E and 4 O Relay 1 contact C Common T Relay 2 N O contact I1 Anti tamper switch V1 Varistor ST1 ST2 Jumper for reset Jumper for relay 1 RL1 Do...

Page 2: ...rm Off Audible Signals 1 beep long Validation of data in programming mode master code proximity badge or time delay Or access code validated 2 beeps short Accessing the programming mode or exiting fro...

Page 3: ...hen the time delay in seconds 01 equal 1 second up to 99 for 99 seconds 00 sets a latched output toggle on toggle off The LED goes out for 1 second and an audible beep indicates the time delay has bee...

Page 4: ...ong beep will sound to confirm that the badge and PIN code have been stored To exit from the programming mode at any time press the key 2 beeps confirm that you have returned to the standby mode Reset...

Page 5: ...tays open the open contact will trigger the alarm relay according to the door relay output Momentary output the alarm time delay begins at the end of the door time delay If the door is maintained open...

Page 6: ...me User number Name Time delays Function n Values Programmed values Keypad key in delay 0 10 10 sec 99 99 sec Door open delay 1 01 1 sec 99 99 sec opened door before alarm 2 00 without alarm 01 10 sec...

Page 7: ...V 1 4 5 12 Distance minimum 60cm maximum 50 m Auxiliary reader terminal connections Input voltage 12V or 230V 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED PR...

Page 8: ...8 Template PROMI500 20 5 mm 105 mm 120 mm 135 mm 23 mm 43 mm 15 mm 38 mm 61 mm 75 5 mm Wiring access area 30 mm x 40 mm...

Page 9: ...9 Template DGLP or DGLI Auxiliary reader Block terminal 43x15 mm 60 mm 96 mm 75 mm 25 mm 6 mm...

Reviews: