Setting a New Master Code

Enter the master code twice (for the first use, the master code default is 12345).  2
beeps will sound and the orange LED illuminates to confirm that you are in
programming mode.
Enter *3 then 5-digit for the new master code. The LED goes out for 1 second and
an audible beep indicates that the new master code is accepted.
Press # to exit from the programming mode. 2 beeps confirm that the reader is in
standby mode.

4 beeps indicate a data computing error.

Setting the Mode and Time Outputs

Enter the master code twice (for the first use, the master code default is 12345).
2 audible beeps, and the orange LED illuminates to confirm entry into
programming mode.

Operating
mode

Enter

0 then the 2-digit mode number:

Mode 00: PIN code and proximity badge, up to 500 users (500 PIN +
500 badges)
Mode 01: Proximity badges only up to 500 users.
Mode 02: PIN codes or proximity badges, up to 500 users.
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Door relay

Enter

1, then the time delay in seconds:

01 equal 1 second up to 99 for 99 seconds.
00 sets a latched output (toggle on/toggle off)
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Alarm Relay

Enter

2, then the time delay in seconds:

01 equal 10 seconds up to 99 for 990 seconds.
00 for alarm off
The LED goes out for 1 second and an audible beep indicates
the time delay has been accepted.

Press # to exit from the programming mode. 2 beeps confirm that the reader is in
standby mode.

4 beeps indicate a data computing error.

Setting New PIN Codes and Badges

Enter the master code twice (for the first use, the master code default is 12345).
2  audible  beeps,  and  the  orange  LED  illuminates  to  confirm  entry  into
programming mode.

Enter  the  user  number  (000  to  499).  If  the  LED  is  green,  the  user  number  is
available,  therefore  present  a  badge  in  front  of  the  main  reader.  Once  the  audible
beep will sound and the green LED will change to orange

Press  *  to  validate  the  badge,  without  the  PIN  code,  and  then  enter  the  next  user
number to program another badge.

OR

To program also a PIN code with the badge, enter a 5-digit code a long beep will
sound to confirm that the badge and PIN code have been stored.

Summary of Contents for PROMI500

Page 1: ...back emf B Request to exit PB1 E Alarm Input M Common PB1 E and 4 O Relay 1 contact C Common T Relay 2 N O contact I1 Anti tamper switch V1 Varistor ST1 ST2 Jumper for reset Jumper for relay 1 RL1 Do...

Page 2: ...rm Off Audible Signals 1 beep long Validation of data in programming mode master code proximity badge or time delay Or access code validated 2 beeps short Accessing the programming mode or exiting fro...

Page 3: ...hen the time delay in seconds 01 equal 1 second up to 99 for 99 seconds 00 sets a latched output toggle on toggle off The LED goes out for 1 second and an audible beep indicates the time delay has bee...

Page 4: ...ong beep will sound to confirm that the badge and PIN code have been stored To exit from the programming mode at any time press the key 2 beeps confirm that you have returned to the standby mode Reset...

Page 5: ...tays open the open contact will trigger the alarm relay according to the door relay output Momentary output the alarm time delay begins at the end of the door time delay If the door is maintained open...

Page 6: ...me User number Name Time delays Function n Values Programmed values Keypad key in delay 0 10 10 sec 99 99 sec Door open delay 1 01 1 sec 99 99 sec opened door before alarm 2 00 without alarm 01 10 sec...

Page 7: ...V 1 4 5 12 Distance minimum 60cm maximum 50 m Auxiliary reader terminal connections Input voltage 12V or 230V 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED PR...

Page 8: ...8 Template PROMI500 20 5 mm 105 mm 120 mm 135 mm 23 mm 43 mm 15 mm 38 mm 61 mm 75 5 mm Wiring access area 30 mm x 40 mm...

Page 9: ...9 Template DGLP or DGLI Auxiliary reader Block terminal 43x15 mm 60 mm 96 mm 75 mm 25 mm 6 mm...