cdvigroup.com
17
INSTALLATION MANUAL
EN
STAR1M - Mullion Mifare
®
card reader
7.3 Common operation
Program or replace a Master badge :
1
ON
2
ON
3
ON
4
ON
ON
OFF
Set DIP2 to OFF
Yellow LED
+ Beep
Present the new master badge
(the old will be erased)
Beep + LED OFF
1
ON
2
ON
3
ON
4
ON
ON
OFF
Set DIP2 to ON
Beep
Blue LED
After 10 seconds
White and Red LED flashing
+ Beep
1 flash : 1 second
Program the unlock time :
Enter in programming
mode
Yellow LED
Press the push button
Each push button press : 1 second
Blue LED
Present the master badge
Default value : 5 seconds, programmable from 01 to 99 seconds
1
ON
2
ON
3
ON
4
ON
ON
OFF
Switch on power
supply
White/Red LED flashing while the
memory is deleted.
Followed by start-up sequence
Delete all cards (reset the reader to the factory
default values)
Switch off power supply
Set DIP1 to ON
Switch off power
supply
1
ON
2
ON
3
ON
4
ON
ON
OFF
Set DIP1 and DIP2 to OFF
Standalone Mode activated
Switch on power supply
To delete all cards switch to wiegand mode
Switch to standalone mode