10
The
SPECIAL FUNCTIONS (Fx)
related to the
MIG pulse
process correspond as follows to those on the wire feeder:
Special function
PARAMETER DISPLAY
Screen - A
PARAMETER DISPLAY Screen - V
Welding mode
Default
Range
TWO STROKE (2T)
FOUR STROKE (4T)
CRA
TER 2T
CRA
TER 4T
SPOT WELDING
STITCH WELDING
CYCLE ST
ANDARD
CYCLE ADV
ANCED
PRE GAS
PrG
0.1s
(0.0 - 2.0)s
●
●
●
●
●
●
●
●
STARTING SPEED
StS
0
-30 - +30
●
●
●
●
●
●
●
●
HOT START
Hot
0
-30 - +30
●
●
●
●
●
●
●
●
STITCH TIME
F05
1.0s
(0.1 - 8.0)s
●
STITCH PAUSE
F06
1.0s
(0.1 - 8.0)s
●
SPOT TIME
F07
3.0s
(0.1 - 20.0)s
●
INITIAL CURRENT
F08
20%
-50% - +100%
●
●
●
●
INITIAL ARC LENGTH
F09
0
-30 - +30
●
(*)
●
(*)
●
(*)
●
(*)
INITIAL CRATER TIME
F10
1.0s
(0.0 - 5.0)s
●
INITIAL SLOPE
F11
1.0s
(0.0 - 5.0)s
●
●
●
●
FINAL SLOPE
F12
1.0s
(0.0 - 8.0)s
●
●
●
●
FINAL CURRENT
F13
-30%
-100% - +50%
●
●
●
●
FINAL ARC LENGTH
F14
0
-30 - +30
●
(*)
●
(*)
●
(*)
●
(*)
FINAL CRATER TIME
F15
0.0s
(0.0 - 5.0)s
●
BURN BACK
bub
0
-30 - +30
●
●
●
●
●
●
●
●
POST GAS
PoG
1.0s
(0.0 - 10.0)s
●
●
●
●
●
●
●
●
FIRST SLOPE (
I
1
TO
I
2
)
F18
0.05s
(0.0 - 1.0)s
●
CYCLE CURRENT
F19
20%
-99% - +100%
●
●
CYCLE ARC LENGTH
F20
0
-30 - +30
●
●
SECOND SLOPE (
I
2
TO
I
1
)
F21
0.05s
(0.0 - 1.0)s
●
ACS / ENCODER SPEED
F28
100A/s
(5 - 500)A/s
●
●
●
●
●
●
●
●
WARNING:
• The STANDARD or ADVANCED welding CYCLE mode can only be activated by opening the
ADVANCED SETUP Menu
-
AD-
VANCED MODE
-
CYCLE
(for further explanations, see the relevant paragraph).
• (*) This
SPECIAL FUNCTION
is only to be found if the
ADVANCED CRATER
function has been activated by accessing the
AD-
VANCED SETUP Menu
-
ADVANCED MODE
-
CRATER - ADVANCED
(for further explanations, see the relevant paragraph).
• It is possible to access editing of the
SPECIAL FUNCTIONS (Fx)
during welding.
• Some of the values edited will be used immediately by the operator, while others will be active from when the next welding
task begins.
• The
HOLD
function is not active within the
SPECIAL FUNCTIONS Menu (SET UP Fx)
.