58
BLOCKS
SETUP Menu
The purpose of this menu is to allow the operator to block or limit use of the welding machine and/or certain welding parame-
ters / functions.
To access the
BLOCKS Menu
from the
SETUP Menu
:
• Turn the
ENCODER K
NOB
- SX
to select the desired icon.
• Push the
ENTER/MEM K
EY
.
The image graphically shows how the type of block is shown on the
VISION S
CREEN
when the welding machine is operating normally.
MENU K
EY
ENTER/MEM K
EY
ENCODER K
NOB
- SX
ENCODER K
NOB
- DX
VISION S
CREEN
SX K
EY
DX K
EY
Fe G3 SI-1 Ø 0.8 Ar 16-20% CO2
PROGRAM 0011
A
L2
V
212 24
Within the
BLOCKS Menu
it is possible to select, by rotating the
ENCODER K
NOB
- DX
, the block required
(this operation does not
require confirmation)
from the
4
options available:
Block type
Description
NONE
BLOCK TYPE
NONE
BLOCK ABSENT or RELEASE MACHINE
Does not allow any block to be activated on the welding machine, but allows the operator
to release the machine if its was blocked previously.
LEVEL 1
BLOCK TYPE
LEVEL 1
PARTIAL BLOCK
The operator can weld using the parameters set prior to the block and may make
adjustments and/or changes to the welding parameters using the knobs on the control
panels on the welding machine and the wire feeder (if fitted).
LEVEL 2
BLOCK TYPE
LEVEL 2
TOTAL BLOCK
The operator can weld only using the parameters set prior to the block and cannot adjust
and/or edit the welding parameters.
USER BLOCK
BLOCK TYPE
USER BLOCK
CURR./WIRE SPEED CHANGE
BLOCKED
ARC LENGTH/VOLTAGE CHANGE
BLOCKED
INDUCTANCE CHANGE
BLOCKED
PROCESS CHANGE
DISABLED
PROGRAM CHANGE
DISABLED
JOB CHANGE
DISABLED
MODE CHANGE
DISABLED
SPECIAL FUNCTION CHANGE
DISABLED
PERSONALISED BLOCK
Used to block or limit some adjustments and/or functions of the welding machine.
To exit the
BLOCKS Menu
and go back to the
SETUP Menu
:
• Push the
MENU K
EY
.