background image

E L E C T R O N I C C I R C U I T S

 

2 CHANNELS FLIP-FLOP RECEIVER REMOTE CONTROL

REMOTE CONTROL

TL-10

TL-10

TL-10

TL-10

The TL-8 is a 2 channels remote control flip-flop receiver supplied by 230 VAC with relay output   working by radio-
frequency. It will recognize the signal from TL-5 or TL-6 emitters, verify the security code and maintain the output 
connected until you stop to press the push button of the emitter.
You could configure your own security code (between 13.122 possibilities) as well as to work with the TL-5 or the TL-6 
Cebek emitters. It includes micro-switches to select the code, antenna output, led and acoustic signal for the 
output as well as connection terminals. 

OPERATING.

TECHNICAL CHARACTERISTICS.

Voltage. ..............................................................................................230 V. AC.
Minimum Consumption. ....................................................................20 mA.
Maximum Consumption. ...................................................................110 mA.
Operating Frequency. .........................................................................433.92 Mhz.
Maximum Reach (approximately) . .....................................................20 - 30 m.
Maximum Load at Output. ................................................................3 A.

Ref. Full9924

MODULE'S SUPPLYING. 

The Circuit TL-10 had to be supplied by 230 VAC. Using an adequate plug and a cable for 

mains connect this last one to the input terminal 230 VAC. Install a fuse and a switch as it is indicated in General 
Wiring Map (see hereafter). Both are necessary to protect the module and for your own security, as it is indicated 
in EEC regulations. Then, verify that you have correctly connected the module. 
Before to connect the module to the mains inserting voltage, please do the rest of connections specified 
hereafter. 

Do not forget that in several part of the module there is voltage (230 VAC),

 for this reason we suggest 

you to be carreful.

OPERATING. 

All CEBEK remote control works with a frequency adjusted at 433.92 MHz. For this reason, the TL-10 

module includes micro-switches (SW-1) allowing to configure a security code between 13.122 possibilities, for 
each module. Then, your module will be different from others, even if they offer same characteristics. 
Seeing the drawing Nº1, you could note that the micro-switches SW-1 have 8 switches with three different positions. "-
", "0" and "+". You have to modify the switches position that you have received in order to select you personal code. 

Do not forget. The receiver and emitter have to have the same code. 

Once emitter and reciver are 

configurated with the same code, you could supply the module. Then, press the push button on the emitter and 
the corresponding output will be connected till you press again the button, to disconnect the output.

ANTENNA INSTALLATION.

 To obtain a maximum and clear reception, you have to install an exterior antenna. 

Seeing the paragraph "General Wiring map", install a metallic antenna with a length of 130 mm. The cable 
between antenna and module had to be shielded and inferior than 25 cm. Connect the negative terminal to 
the ground. 

OUTPUT CONFIGURATION.

 Even if the receiver TL-10 have been developed to control its corresponding emitter 

with 2 channels (TL-6 module), it also could be controlled by the TL-5 module. 1 Channel emitter. Then, you have 
to select between two push buttons the wished receiver output. 
From the factory, the module is supplied to be controlled by the TL-6 module (with JP1 Jumper closed). To control the 
TL-10 thanks to the TL-5 module, you have to select which output will be connected after to press the push button. 
Then, you have to remove the “JP” piece of the JP1 Jumper and with it closed the JP2 jumper. Selecting one of two 
jumpers, you could select the required output. 

GENERAL WIRING MAP.

1

+

-

0

1

2

3

4 5 6 7 8

SW-1

Fig. 1.

Jumper no Closed

(Open).

Closed

Jumper

JP

JP

Piece

230 V. AC. Mains

Mains

Switch

250 mA.

Fuse

Led 2

Relay 2

Relay 1

Led 1

SW-1

JP1

Acoustic

Signal

Antenna 130 mm.

Ground

JP2

NO

NC

Common

NO

NC

Common

O

u

tp

u

2

O

u

tp

u

1

+

-

0

1

2

3

4

5

6

7

8

Module

TL-10

2

3

0

V

1

2

V

Antenna

Output

LOADS CONNECTION.

Common

(NO) Normally Open

(NC) Normally Closed

Device,

Load.

INFORMATION ABOUT THE OUTPUT.

 During the operating mode and according to its load, it could happen a 

fluctuation or an incorrect working of the 
output. In such case, you have to install an 
anti-spark circuit between both contacts of 
the used relay, as it is indicated on the 
schedule.

100nF/400 V.

47

W

 1/2W.

Load’s supply

OUTPUT CONNECTION. LOAD.

 

The TL-10 output is controlled by a relay, and accept any device up to 3 A. The 

relay have three output terminals: The normally open quiescent (NO), the normally closed quiescent (NC) and 
the common. This mechanism operate like a switch with two terminals NO and Common. For the inverse 
function you have to use the NC and Common. In the drawing hereafter, you could see a typical connection 
with a 12 V D.C and 230 V A.C devices. 

230 V. AC. CONNECTION

12 V. DC. CONNECTON

12 V. DC

Common

Common

(NO) Normally Open

(NO) Normally Open

(NC) Normally Closed

(NC) Normally Closed

Load,

Device

Load,

Device

230 V. AC.

2

2

TECHNICAL CONSULTATIONS.

If you have any doubt, you could contact your wholesaler or our Technical  Department.
- Via E-Mail,  

sat

@cebek.com     |    

by mail

 

 P.O Box 23455  - 08080  BARCELONA - SPAIN.

CEBEK is trade make of FADISEL S.L. more than 300 module’s are 
avaible in stock for any purpose 

request our CATALOGUE, 

or visit 

our Web.

 Http://www.cebek.com

All the module’s CEBEK have 

3 years of total warranty 

in thecnical 