Manual MicroProgel

©

 TC 323

9 fixed and 9 open programs with 31 steps

Digital display with error code

Possibility to delayed start.

Self diagnostic

Summary of Contents for MicroProgel TC 32

Page 1: ...ammarby Fabriksv g 43 S 120 33 STOCKHOLM Tel 46 8 658 50 04 Fax 46 8 669 60 98 G teborg Argongatan 8 S 431 53 M LNDAL Tel 46 31 87 51 30 Fax 46 31 87 97 61 Web www cebex se Mail Info cebex se Manual M...

Page 2: ...user PERS and 9 pre configured FIX cycles 6 Sect 4 Entering or modifying the selected cycle 6 Sect 5 Running a cycle 8 Sect 6 Activating the timer for the delayed running of the cycle 8 Sect 7 Settin...

Page 3: ...cycle belongs to the user group customisable The FIX light indicates that the cycle belongs to the group of cycles pre configured by the installer Display STEP of the step in progress If the controll...

Page 4: ...G and STEP displays indicate the cycle and step in progress The group of lights indicate whether in the current step the temperature is increasing heating stabilising or decreasing cooling The energy...

Page 5: ...e the last time the counter was reset by the user the kWh light is on In START mode Normally the controller displays the temperature of the kiln in C on the MAIN display and the C light is on Pressing...

Page 6: ...ep flashing If the cycle is empty that is has not yet been entered the time shown will be 00 00 otherwise the previously set time in hours minutes will be displayed e g 02 25 indicates a time of 2 hou...

Page 7: ...layed is 01 00 that is 1h flashing press En te r the controller prompts the setpoint for the first time setpoint pair STEP no 1 press to increase the value displayed or to decrease it until the temper...

Page 8: ...d to display the following values in sequence Operating setpoint Time elapsed since the start Partial energy consumed since the last start Total energy consumed this value can be reset see the corresp...

Page 9: ...ing for the end of the delay time by pressing the S T O P S T A R T button The time displayed can be increased or decreased using the and buttons WARNING changes made in this way to the start delay ti...

Page 10: ...er ER31 Hardware fault Contact the installer ER41 ER42 Thermocouple continuity failure not connected or connected incorrectly Check the thermocouple and connections ER43 Cold junction temperature sens...