13

· To 

save

in a different program, make your selection by

briefly pressing the push-button 

Q

, then hold down the

push-button 

Q

for more than 3 seconds.

3.6.3

Save from a saved program

Beginning with a previously saved program, the operator
may edit the data in memory to update the program itself,
or to find new parameters to save in another program.

3.6.3.1 Update

· After turning on the machine, select the parameters to
be edited and edit them.
· Weld, even briefly.
· Hold down the 

Q

button for more than 3 seconds, until

the save is confirmed (program symbol changes from
flashing to steady).

3.6.3.2 Save in a new program

· After turning on the machine, select the parameters to
be edited and edit them.
· Weld, even briefly.
· Briefly press the selector 

Q

until the desired program is

displayed.
· Hold down the 

Q

button until the save is confirmed (pro-

gram symbol changes from flashing to steady).

4  REMOTE CONTROLS

The following remote controls may be connected to
adjust the welding current for this welding machine:
Art. 193 Foot control (used in TIG welding) 
Art (1262) TIG UP/DOWN Torch.
Art 1192+Art 187 (used in MMA welding)
ART. 1180 Connection to simultaneously connect the
torch and the pedal control.
ART. 193 may be used in any TIG welding mode with this
accessory.

Remote controls that include a potentiometer regu-
late the welding current from the minimum to the
maximum current set via the knob O.
Remote controls with UP/DOWN logic regulate the
welding current from the minimum to the maximum.

The remote control settings are always active in the 

PL

program, while they are not active in a saved program.

5  MAINTENANCE 

Any maintenance operation must be carried out by qua-
lified personnel in compliance with standard  CEI 26-29
(IEC 60974-4).

5.1  GENERATOR MAINTENANCE

In the case of maintenance inside the machine, make
sure that the switch 

AC

is in position "O" 

and that the

power cord is disconnected from the mains. 

It is also necessary to periodically clean the interior of the
machine from the accumulated metal dust, using com-
pressed air.

5.2  

PRECAUTIONS AFTER REPAIRS.

After making repairs, take care to organize the wiring so that
there is secure insulation between the primary and secon-
dary sides of the machine. Do not allow the wires to come
into contact with moving parts or those that heat up during
operation. Reassemble all clamps as they were on the origi-
nal machine, to prevent a connection from occurring
between the primary and secondary circuits should a wire
accidentally break or be disconnected.
Also mount the screws with geared washers as on the ori-
ginal machine.

Summary of Contents for BI-WELDER TIG 2040 DC-HF

Page 1: ...be on your right side Connect the work cable to the workpiece as close as possible to the area being welded cut Do not work next to welding cutting power source EXPLOSIONS Do not weld in the vicinity...

Page 2: ...ot suitable for use outdoors in the rain unless it is protected Suitable for hazardous environments Note 1 The machine has also been designed for use in envi ronments with a pollution rating of 1 See...

Page 3: ...it be necessary to reduce the current during weld ing without shutting of the arc for instance when chang ing the welding material or working position moving from horizontal to upright etc press and i...

Page 4: ...t starting from the minimum reaches the set current value 0 10 sec Warning only those LEDs that refer to the chosen weld ing mode will light i e in continuous TIG welding the LED T representing the pu...

Page 5: ...e electrode The diameter of the ceramic nozzle must be 4 to 6 times the diameter of the electrode The most commonly used gas is normally ARGON because it is less costly than other inert gases but you...

Page 6: ...ART 193 may be used in any TIG welding mode with this accessory Remote controls that include a potentiometer regu late the welding current from the minimum to the maximum current set via the knob O Re...

Page 7: ...E ESTA PARTE EST DESTINADA EXCLUSIVAMENTE AL PERSONAL CUALIFICADO ESTA PARTE DEDICADA EXCLUSIVAMENTE AO PESSOAL QUALIFICADO T M OSA ON TARKOITETTU AINOASTAAN AMMATTITAITOISELLE HENKIL KUNNALLE DETTE A...

Page 8: ...72 Art 265...

Page 9: ...20 SUPPORTO CIRCUITO CIRCUIT BOARD SUPPORT 21 CIRCUITO FILTRO FILTER CIRCUIT 22 PANNELLO ANTERIORE FRONT PANEL 23 MANOPOLA KNOB 24 SUPPORTO CIRCUITO CIRCUIT BOARD SUPPORT 25 CIRCUITO DISPLAY DISPLAY...

Page 10: ...74 Art 265...

Page 11: ...E K MARRONE BROWN J ARANCIO ORANGE I ROSA PINK CODIFICA COLORI WIRING DIAGRAM CABLAGGIO ELETTRICO COLOUR CODE L ROSA NERO PINK BLACK M GRIGIO VIOLA GREY PURPLE N BIANCO VIOLA WHITE PURPLE O BIANCO NER...

Reviews: