FOR YOUR SAFETY

 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN 

THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

 

SAFETY PRECAUTIONS 

FOR YOUR SAFETY. THE FOLLOWING PRECAUTIONS SHOULD BE FOLLOWED AND ENFORCED.

 

Instructions must be posted in a prominent location and all safety precautions taken in the event the user smells gas. 
Obtain this information form you r local gas supplier.

 

1. IF YOU SMELL GAS:

 

A. OPEN WINDOW                                                     C. EXTINGUISH ANY OPEN FLAME  
B. DON'T TOUCH ELECTRICAL SWITCHES            D. IMMEDIATELY CALL YOUR GAS SUPPLIER

 

2. LIGHTING - Follow the instructions on page 3 and on label attached to right side panel of unit. 
3. DO NOT place anything over flue opening. 
4. DO NOT place combus tible or non-combustible materials in the vicinity of the griddle as this could cause fires or obstruct air to 

the main burners. 

5.  This installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 

(latest edition), or the National Gas Installation Code, CAN/CGS-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 
as applicable. 

6.  Provide adequate air supply and ventilation. 
7.  Provide adequate clearance for air openings into the combustion chamber. 
8.  Provide clearances for servicing and operation. This unit is for use only on non-combustible floors. Minimum clearances from 

combustible and non-combustible construction: 6 inches from side and 6 inches from back. 

9.  Griddle must be disconnected from gas supply during pressure testing of pipelines in excess of 1/2 psig (3.45KPa) and isolated 

(by turning off the manual gas shut-off valve) during any testing to or less than 1/2 psig. 

10. Retain this manual for future reference. 

MODEL NO.

 

GAS DATA

 

GENERAL DATA

 

 

 

 

 

 

GRIDDLE AREA

 

 
 

*TOTAL BTU

 

NO. OF BURNERS

 

DIM A

 

DIM B

 

in inches

 

 
 

 
 

 
 

 
 

 
 

 
 

BG12 

16,000

 

1

 

12

 

8

 

18x 12

 

BG24

 

32,000

 

2

 

24

 

20

 

18x24

 

BG36

 

48,000

 

3

 

36

 

32

 

18x36

 

BG48

 

64,000

 

4

 

48

 

44

 

18x48

 

 

*NATURAL AND PROPANE AT 4 in. AND 10 in. W.C. 

 

THIS GRIDDLE INTENDED FOR OTHER THAN HOUSEHOLD USE. DESIGN CERTIFIED FOR USE ONLY ON NON-
COMBUSTIBLE FLOORS. MINIMUM CLEARANCE FROM COMBUSTIBLE AND NON-COMBUSTIBLE CONSTRUCTION: 
6 INCHES FROM SIDE AND 6 INCHES FROM BACK PANEL.

 

Summary of Contents for BG 12

Page 1: ...wer with baffle 7 Supplied with adjustable NSF listed legs 8 A G A design certified 9 MEA Listed 10 NSF Listed FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance This installation must conform with local codes with the National Fuel Gas Code ANSI Z223 1 latest edition Natural Gas Installation Code CAN CGA B149 1 or the ...

Page 2: ...he National Gas Installation Code CAN CGS B149 1 or the Propane Installation Code CAN CGA B149 2 as applicable 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air openings into the combustion chamber 8 Provide clearances for servicing and operation This unit is for use only on non combustible floors Minimum clearances from combustible and non combustible construction...

Page 3: ...ion before attempting to light the griddle Inspect the burners to see that they are properly seated on the support bracket at the rear and properly located on the burner orifices The griddle is now ready for lighting LIGHTING INSTRUCTIONS These lighting instructions are to be followed for installation only For normal operation follow the simple instructions on the gas specification label attached ...

Page 4: ...keep your griddle clean and sparkling but will prevent grease accumulations from forming A well cleaned griddle will give you many years of service and perform more efficiently OUTSIDE SERVICE Should you require help contact the factory your factory representative or your local service company FOR QUALIFIED SERVICE PERSONS ONLY When servicing of unit is required contact a qualified service agency ...

Page 5: ... Pilot Light Adj Valve F019A F019A F019A F019A 10 Gas Valve Knob M241A M241A M241A M241A 11 Front Panel T683A T663A T689A T701A 12 Nut Retainer P297A P297A P297A P297A 13 Grease Drawer T704Q T704Q T704Q T704Q 14 Bottom Panel T708A T705A T706A T704A 15 Body Wrap T662A T668A T669A T694A 16 Pilot Burner Ass y N F135A F135A F135A F135A Pilot Burner Ass y P F134A F134A F134A F134A 17 Adjustable Leg Set...

Reviews: