FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
SAFETY PRECAUTIONS
FOR YOUR SAFETY. THE FOLLOWING PRECAUTIONS SHOULD BE FOLLOWED AND ENFORCED.
Instructions must be posted in a prominent location and all safety precautions taken in the event the user smells gas.
Obtain this information form you r local gas supplier.
1. IF YOU SMELL GAS:
A. OPEN WINDOW C. EXTINGUISH ANY OPEN FLAME
B. DON'T TOUCH ELECTRICAL SWITCHES D. IMMEDIATELY CALL YOUR GAS SUPPLIER
2. LIGHTING - Follow the instructions on page 3 and on label attached to right side panel of unit.
3. DO NOT place anything over flue opening.
4. DO NOT place combus tible or non-combustible materials in the vicinity of the griddle as this could cause fires or obstruct air to
the main burners.
5. This installation must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition), or the National Gas Installation Code, CAN/CGS-B149.1, or the Propane Installation Code, CAN/CGA-B149.2
as applicable.
6. Provide adequate air supply and ventilation.
7. Provide adequate clearance for air openings into the combustion chamber.
8. Provide clearances for servicing and operation. This unit is for use only on non-combustible floors. Minimum clearances from
combustible and non-combustible construction: 6 inches from side and 6 inches from back.
9. Griddle must be disconnected from gas supply during pressure testing of pipelines in excess of 1/2 psig (3.45KPa) and isolated
(by turning off the manual gas shut-off valve) during any testing to or less than 1/2 psig.
10. Retain this manual for future reference.
MODEL NO.
GAS DATA
GENERAL DATA
GRIDDLE AREA
*TOTAL BTU
NO. OF BURNERS
DIM A
DIM B
in inches
BG12
16,000
1
12
8
18x 12
BG24
32,000
2
24
20
18x24
BG36
48,000
3
36
32
18x36
BG48
64,000
4
48
44
18x48
*NATURAL AND PROPANE AT 4 in. AND 10 in. W.C.
THIS GRIDDLE INTENDED FOR OTHER THAN HOUSEHOLD USE. DESIGN CERTIFIED FOR USE ONLY ON NON-
COMBUSTIBLE FLOORS. MINIMUM CLEARANCE FROM COMBUSTIBLE AND NON-COMBUSTIBLE CONSTRUCTION:
6 INCHES FROM SIDE AND 6 INCHES FROM BACK PANEL.
2