11. FAULTS AND TROUBLESHOOTING
FAULT
SOLUTION
The pot doesn’t reach the pressure.
Observations: The GM cooking pots can work with
pressure when conditions require it. This depends on
various factors, quantity of liquids, solids, oil in the inner
pot and the room and food temperatures.
Don’t confuse the pressure with the pot cooking and
working correctly. If the pot has warmed up and cooked in
the selected time, it means it is operating as it should and
an error cannot be determined.
- Make sure the back cover and the silicone ring is placed
correct-ly.
- Check that the pressure valve is in the closed position.
- Make sure the safety valve is placed correctly.
- Press the cover firmly after turning to make sure its closed.
- Add 1l of water, select pressure menu, 20 minutes at
medium pressure, 200ºC and cook.
Repeat the same process with the steam and pressure
menus.
If the pot takes pressure it means it works correctly.
In order for the pot to reach pressure, the selected
temperature must be higher than 130ºC and contain enough
liquid in the inner pot.
-The rubber rings are in bad shape, replace them.
The cooker does not switch on
-Make sure the power cable is properly connected to the
cooker.
- Try it with a different socket.
- Try with a different power cable provided by Cecotec.
Is it fine to open the cooker whilst cooking
Only when the cooker has not yet reached pressure but it is
not recommended as it will lose steam.
E1 error code on the digital display
Circuit failure. Contact technical support.
The cooker won’t read things out loud.
Check section. 4.1. and verify settings. If the problem
continues, contact technical support.
The cooker deducts the time whenever programmed (3 +
hours) or when a menu is selected.
Check section .7 and verify the settings. If the problem
persists, contact technical support.
The cooker does not heat up
Place 1 l of water and select the baking menu at 200 ºC for
10 minutes.
E4 error code on the digital display
- Check section .6 and review the cooking states of the cooker.
- The pressure gauge fails. Contact technical support
E4 error code on the digital display
- Overheating. Let the cooker cool down without using it for
up to 24h
- Always add liquid over the minimum marker of the inner pot
and select a menu.
- If the error shows up right when the appliance is switched
on, please contact technical support.
E2 error code on the digital display.
Contact technical support.
12. TECHNICAL SPECIFICATIONS
Model: Olla GM Modelo H
Product reference: 02032
1000 W, 200-240 V~ 50/60 Hz, IP XO
Made in China | Designed in Spain