background image

 

CabSafe

ä

 

Door Protection 

Quick Start Guide 

 

Thank you for purchasing the CEDES CabSafe elevator 
door  protection  system.  This  “Quick  Start”  guide 
provides basic information for the system concept. This 
document does not replace the installation and operating 
instructions for the components included in this kit and 
available online at 

www.cedes.com

.   

Consult the installation and operation instructions 
relevant to the individual devices included in this kit for 
additional information regarding the system, additional 
warnings, requirements and device-specific 
specifications: 

115 944 CabSafe System Operating Manual; and 

 

116 106 cegard/Pro (CabSafe 2D) Operating Manual

 

Download these documents at: 

www.cedes.com

.   

 

For glass elevators

, please see operating instructions 

for additional requirements. 
 

 

Important Notes:

  

 

 

This door protection system must only be installed and 
commissioned  by  qualified  elevator  installation 
personnel.

 

 

 

Before  beginning  installation  of  this  door  protection 
system, you must be sure that the elevator has been 
properly  placed  “Out  of  Service”  to  ensure  that  the 
elevator and related components will not be allowed to 
move  during  the  installation.  You  must  follow  all 
applicable safety protocols, rules and regulations that 
apply.

 

 

 

Upon 

completion 

of 

the 

installation 

and 

commissioning  of  this  door  protection  system, 
qualified  elevator  installation  personnel  must  ensure 
that the installation complies with all applicable local, 
regional  and  national  regulatory  requirements,  and 
that  the  operation  of  the  elevator  control  system, 
including this light curtain, perform in accordance with 
the application and regulatory requirements.

 

 

System Overview:

 

This CabSafe system is designed for use as part of an 
elevator  door  protection  system  in  accordance  with 
ASME ANSI A17.1-2019 / CSA B44-19.  The CabSafe 
2D  forms  an  invisible  field  of  criss-cross  beams  that 
detect the presence of persons or objects between the 
doors.    The  CabSafe  3D  detects  persons  or  objects 
approaching the elevator entrance.  These devices are 
connected to a CabSafe Controller. When an object is 
detected,  the  output  from  the  CabSafe  controller 
changes  state  to  indicate  that  the  doors  should  be 
reopened  since  a  person  or  object  is  present  in  the 
respective detection field. 

  

 
 

CabSafe 2D (cegard/Pro):

 

 

 

The CabSafe 2D transmitter and receiver are normally 
mounted on the doors in a center-opening application or 
on  the  door  and  the  slam  post  in  a  side-opening 
application.  The maximum door speed should be less 
than 0.5 m/s (1.64 ft/s). The lowest beam must be less 
than 25 mm (1 inch) from the sill.  The optical Axis must 
be within 

±

 5˚ between the transmitter and receiver. 

 

 

 
 
 
 
 
 
 
 
 

 

Attach  a  felt  strip  in  the  center  of  the  associated 
mounting or spacer profile to reduce any vibration that 
might  occur.  Once  the  CabSafe  2D  components  are 
mounted,  connect  the  cables  from  the  devices  to  the 
CabSafe  Controller.  Then  secure  the  cables  in  place, 
allowing  enough  slack  so  that  they  can  bend  freely, 
without becoming snagged on moving parts. Use cable 
guide wires on door(s) to prevent excessive cable sway.

 

 

CabSafe 3D:

 

 

 

The  CabSafe  3D  is  a  time-of-flight  (TOF)  transom-
mounted device that projects a detection field in front of 
the elevator cab entrance.  For OEM applications where 
the  transom  already  has  a  cut-out  for  the  sensor,  the 
mounting is straightforward using an optional backplate  
included  with  the  sensor  and  two  (2)  security  screws 
(spanner type).  

The  cable  must  exit  right  from  the  sensor  as  you 
look into the cab (regardless of left-open, right-open 
or center-open application).  
 

 

 
 
 
 
 
 
 
 

The above figure shows a “Sensor Mounted in Center” 

 

For center mounting applications, the sensor should be 
centered  in  the  opening  as  shown  above.    For  side-
mounting applications, the sensor must: 

 

Be positioned no more than 240 mm (9.5 inches) 
from the slam post (Distance “D”).  

 

Be less than 300 mm (12 inches) from the landing 
side of the landing door (Distance “S”).  

Route the cable from the CabSafe 3D to the CabSafe 
controller.  Connect the cable to the CabSafe 3D and 
then  secure  the  sensor  in  the  transom.  An  optional 
stainless-steel back of transom bracket is also available 
for modernization applications. 

 

CabSafe Controller: 

CabSafe controllers are available with a wide ranging or 
24  V  DC 

±

  20%  input  power.  The  CabSafe  sensor 

components plug into the CabSafe Controllers the same 
way for all variants.  Namely, 

 

CabSafe 2D Transmitter = 3-pole Plug 

 

CabSafe 2D Receiver = 4-pole Plug 

 

CabSafe 3D Sensor = 6-pole Plug. 

 

Power is connected to the corresponding pins on power 
connector.  See labels on device for details.  

 

 

 

 

CabSafe 200 with 

Relay Output 

85-265 VAC / 

19.2-37 VDC / 

120-300 VDC 

 
 

CabSafe 100 with 

Relay Output 
19.2-37 VDC 

CabSafe 100 with 

Solid-State Output 

19.2-28.8 VDC 

Optical 
Axis 