   02PN8 HI-PE/CF --- Rev. F044GB60K10

7

IV - PROGRAMMING

Characteristics

Programming parameters not applicable

SS, G1, G2, TP, CS, AU, FQ

New

 

programming parameters, or those only present

on some standard models

CM, RO, TI

Modified programming parameters

IS

New

 

functions, or those only present on some

standard models

Direct display of the level of
security IS

New programming parameters, or those only present on some standard
models

Code

Meaning

Possible
values

Type

Notes

CM

Cabin model

0-4

C/R

Siting of an HI-PE/CF antenna inside a metal structure generally requires a test
to be carried out by CEIA technicians. For installation to be possible in cabins
with different characteristics, these tests must be carried out on a sample unit of
each type.
CEIA stores the optimum configuration of the device for each cabin which has
been tested.
The CM command allows the installer to select the configuration according to the
cabin used.
The correspondence between the numerical values of the CM setting and the
type of cabin is specified in the CEIA test report, which also specifies the string of
characters which appears on the display during selection as a concise
denomination of the type of cabin. The 0 setting is usually reserved for the open-
space configuration without surrounding metal structure.

E.g. :

Message

Numerical Comment

value

F R E E 6 8 0

0

Metal detector without surrounding metal structure,
useful passage width 680mm (model HI-
PE/CF-AS-140

C A B I N A   1

1

Metal detector installed in a cabin of the 1

st

  type

C A B I N A   2

2

Metal detector installed in a cabin of the 2

nd

  type

C A B I N A   3

3

Metal detector installed in a cabin of the 3

rd

  type

V O I D

4

Free memory, usable for a new configuration in the

future

RO

Read out of the
reception signal

0-9995

R

This displays the result of  the processing of the reception signals,  by means of a
numerical indication. It can display values from 0 to 9,995.

Summary of Contents for HI-PE/CF

Page 1: ...TECTOR HI PE Additional information for the HI PE CF Series ATTENTION Keep the transducer matched with the electronics unit and the Technical Booklet which have the same serial number Program Version...

Page 2: ...OR USE 6 SWITCHING ON THE METAL DETECTOR 6 IV PROGRAMMING 7 Characteristics 7 New programming parameters or those only present on some standard models 7 ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND IS...

Page 3: ...of the 02PN8 HI PE model The advantages of using this new Metal Detector are the following a notable reduction in the need for branch staff to act to check inward and outward bound traffic increase i...

Page 4: ...ications HI PE CFPNAS600 Corresponds to model HI PE PN AS 600 Useful passage width 680 820mm HI PE CF No external modification compared with version HI PE CN AS 140 Useful passage width limited to 740...

Page 5: ...er is provided with any technical notes needed for installation including instructions on how to orientate the antenna when attaching it to the base structure Orientation of the columns is achieved by...

Page 6: ...n the Metal Detector After turning ON the equipment an audible signal will sound and the display of the electronics unit will show the following information CEIA HIPE CF WAIT Fig III 1 MANUFACTURER MO...

Page 7: ...d allows the installer to select the configuration according to the cabin used The correspondence between the numerical values of the CM setting and the type of cabin is specified in the CEIA test rep...

Page 8: ...the inhibition signal it is necessary to wait for time tr before the detector reactivates ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND IS PROGRAM IS DISPLAY MESSAGE SECURITY LEVEL APPLICATION SAMPLES...

Page 9: ...e electronics unit can be replaced in less than one minute Colour light grey RAL 7040 Alarms Audible signal Buzzer 90 dBA 1 m Relay output Switch contact NA NC C 1 A 24 Vdc Reset PP input automatic or...

Page 10: ...er 1 19045 Cover complete with lock 1 4074 Electronics unit key kit 1 8471 In all component orders please indicate the serial number of the device Accessories Validity revision 1 0 9 11 1999 Replaceme...

Page 11: ...93 68 CEE concernant la basse tensions Dieses Produkt entspricht den Anforderungen an Niederspannungsger te gem der Norm 73 23 EEC und nachfolgender in der Norm 93 68 EEC angegebener nderungen El prod...

Reviews: