CM
Cabin model
0-4
C/R
Siting of an HI-PE/CF antenna inside a metal structure generally requires a test
to be carried out by CEIA technicians. For installation to be possible in cabins
with different characteristics, these tests must be carried out on a sample unit of
each type.
CEIA stores the optimum configuration of the device for each cabin which has
been tested.
The CM command allows the installer to select the configuration according to the
cabin used.
The correspondence between the numerical values of the CM setting and the
type of cabin is specified in the CEIA test report, which also specifies the string of
characters which appears on the display during selection as a concise
denomination of the type of cabin. The 0 setting is usually reserved for the open-
space configuration without surrounding metal structure.
E.g. :
Message
Numerical Comment
value
F R E E 6 8 0
0
Metal detector without surrounding metal structure,
useful passage width 680mm (model HI-
PE/CF-AS-140
C A B I N A 1
1
Metal detector installed in a cabin of the 1
st
type
C A B I N A 2
2
Metal detector installed in a cabin of the 2
nd
type
C A B I N A 3
3
Metal detector installed in a cabin of the 3
rd
type
V O I D
4
Free memory, usable for a new configuration in the
future
RO
Read out of the
reception signal
0-9995
R
This displays the result of the processing of the reception signals, by means of a
numerical indication. It can display values from 0 to 9,995.