HI-PE multi-zone --- Rev.
FI 050 GB 60K10 v2_1
19
Other messages
Emergency battery power – mains voltage absent
Display
Buzzer
Meaning
- - - - B
Fig. III-4a
-
Emergency battery power supply is only indicated by a flashing letter “B” on the right of
the display.
Warnings
Display
Buzzer
Meaning
GATE EV
Self-diagnosis (example shows message indicating antenna damaged or disconnected
from the electronics unit)
WAIT
Fig. III-4b
Implementation phase of operating parameter modification. Metal Detector not
operational (alarm relay activated).
Messages activated via the keypad
When keys
or
are pressed, the display shows, in sequence, the values of some operating
parameters without having to enter programming mode (see also Programming section).
Normal
operation
indicator
Security level
Number of
inward transits
Number of
outward
transits
Normal
operation
indicator
Action
Parameter
Possible messages
AU
(Autoset)
AUTOSET
Standard operation obtained via the
AU
(Autoset) function.
N.B.: the AUTOSET function is pre-set in the factory for all detectors.
IS
NILECJ 1
Operation in line with standard NILECJ 0601.00, level 1, obtained via the
IS (International Security Standards) function.
For the other possible settings, see Programming section.
(International
security
standards)
NILECJ 1
MODIFIED
NILECJ 1
:
Operation in line with standard NILECJ 0601.00, level 1, obtained via the
IS (International Security Standards) function, but with sensitivity setting
modified (parameter SE).
The two messages alternate on the display.
NO SET
Operation differs from the standards selectable using the AU and IS
functions. In addition to the sensitivity, it is possible to adjust another
parameter which influences the response of the detector to metals (see
sub-section “Received signal parameters” in the Programming section).
CI
(Count in)
C I 102
Number of transits through the gate in the direction defined by parameter
GD (gate direction).
The read-out is updated in real time.
Fig. III-5
CO
(
Count out
)
CO 15
Number of transits through the gate in the opposite direction to that defined
by parameter GD (gate direction).
The read-out is updated in real time.
N.B.: the messages described above remain activated until the
or
key is pressed: this allows the operator to
check, for example, the number of inward transits over the whole shift.