HI-PE multi-zone --- Rev.
FI 050 GB 60K10 v2_1
25
Code
Meaning
Possible
values
Type
Notes
decimal)
•
the total number of alarms (
T
, 6 figures)
All counters are reset by the CR function.
Note
: during local programming, the values are displayed according to a cyclical sequence
by pressing the
and
keys.
Note:
Passages carried out in the opposite direction to that selected with the GD function
are not counted.
CR
Alarm counter
reset
-
C
This command requests confirmation
NOTE There are two counters, one at operator level and one at supervisor level (see
also “Advanced Programming” section)
: only the counter at the current level of
programming is reset.
WT
Working time of
the system
0-999999 R
GN
General
environmental
noise
measurement
YES,NO
C
Displays the value of the signal received by the probe. 100 different values ranging from 0
to 99 can be displayed. Readings under 6 are also displayed via bar-graph:
1 I
6 I I I I I I
Local programming:
display of the noise level is activated by selecting "
YES
" and exiting
from the programming.
Measuring ends when the function is turned off (
GN= NO
): on exiting from the programming
mode the display will show the normal operating message (sensitivity level).
Remote programming:
this function is activated by pressing the
ENTER
key: the numeric
values will then appear on the right, from 0 to 99, continually updated. To end
measurement, press any key
If both GN and EN functions are activated, function EN has priority.
EN
Environmental
electromagnetic
noise
measurement
YES,NO
C
Similar to the GN function, but for electromagnetic environmental noise
NOTE: the function is terminated automatically after
2 minutes.
NOTE when the measurement phase is terminated a short beep is uttered and the display
shows the message:
RESTART
SL
Self-diagnostic
level
P, C
C,R,S
P
limited programme of checks, (without monitoring of TX, RX and control sections).
C
complete programme of checks.
Partial self-diagnosis (SL=P) is useful for technical testing.
In the standard settings this parameter can be accessed by the superuser only
PV
Management
programme
version
- R
GD
Gate direction
1,2,3,4
C,R
Selects the direction of transit through the antennae relative to the positioning of the
archway and the type of alarm signalling.
GD=1
if you look at the gate from the point of entry, the transmitter antenna should be on
the right. The LED bar activated is
BD1
.
GD=2
if you look at the gate from the point of entry, the transmitter antenna should be on
the left. The LED bar activated is
BD2
.
GD=3
similar to GD=1, but both LED bars are activated.
GD=4
similar to GD=2, but both LED bars are activated.
GD=5
similar to GD=1, but in the case of an alarm LED bar BD1 identifies the metal
mass, whilst bar BD2 lights up completely.
GD=6
similar to =2, but in the case of an alarm LED bar BD2 identifies the metal mass,