HI-PE multi-zone --- Rev.
FI 050 GB 60K10 v2_1
27
Code
Meaning
Possible
values
Type
Notes
PO
Output level
HEA.C
ASTM
50364
ACGIH
IEEE
364LO
ENVDE
R,C
The parameter is pre-set in the factory according to the regulations regarding human
exposure to electromagnetic fields. applicable in the destination country. Any modification to
this pre-setting is the responsibility of the installer. For further information contact the
competent bodies. CEIA’s technical/sales department can provide further clarification.
HEA:C
Health Canada - Medical Devices Bureau
ASTM
ASTM FXXXX-99 "Standard Specification for Field Strength of Hand-Held Metal
Detectors"
(U.S.A.)
50364
EN50364:2001 (basic restrictions)
ACGIH
American Conference of Governmental Industrial Hygienists-1999
IEEE
standard IEEE C95.1-1999
364LO
EN50364: 2001 (derivated reference levels)
ENVDE VDE 0848-3-1
SN
Serial number of
the Metal
Detector
- R
PW
Power ON/OFF
ON,OF
C
ON
metal detector ON
OF
metal detector on stand-by
For details of the procedure, see the “Use of the Metal Detector” section.
Selects the LED bar signalling mode:
ZN
Number of zones FLOA
4
8
C,R
FLOA
a single floating zone: a group
of LEDs lights up at the height
of transit of the metal mass (20
different zones of variable
height and position)
4
when a metal mass is
detected, one of 4 distinct
zones, each of fixed height
and position, lights up.
8
when a metal mass is
detected, one of 8 distinct
zones, each of fixed height
and position, lights up.
ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND "IS"
PROGRAM
IS
DISPLAY
MESSAGE
SECURITY LEVEL / APPLICATION
SAMPLES
1
NILECJ 1
Standard : NILECJ-STD-0601.00 Security Level 1
AM9
2
NILECJ 2
Standard : NILECJ-STD-0601.00 Security Level 2*
AM7; AN7
3
NILECJ 3
Standard : NILECJ-STD-0601.00 Security Level 3*
AM5; AN5
4
NILECJ 4
Standard : NILECJ-STD-0601.00 Security Level 4
AM3; AN3; B6
5
NILECJ 5
Standard : NILECJ-STD-0601.00 Security Level 5
AM1; AN1; B2
6
3GUN TST
Standard : 3-GUN-TEST (FAA - USA)
OTP and weapons foreseen by the Standard
7
3GUN TSE
Standard : ENHANCED 3-GUN-TEST
OTP and weapons foreseen by the Standard
8
SPH.44.4
-
Sphere AISI 420 ø44.45
9
SPH.41.3
-
Sphere AISI 420 ø41.275
* N.B.: security levels NILECJ 2 and NILECJ 3 include the additional requirements foreseen by the Standard.
The unit is programmed in the factory to ensure operation according to the IS standards for the passage
width listed in the "
Factory Acceptance Test Report
" included at the end of the manual. If, for any reason, the
passage width has been changed, this correspondence is not guaranteed