Parameters accessible from remote programming only
Function code
:
C= command
R= status request
S= the command can only be accessed from the super-user level
Code
Meaning
Possible value
Type Notes
CI
Number of
inward
transits
0-999999
R
This function displays the number of transits made through the gate, in the direction defined
by parameter GD, since the last time the alarm counter was reset (command CR).
During normal operation, the current value of this parameter can be seen on the display if the
. or
key is pressed
CO
number of
outward
transits
0-999999
R
This function displays the number of transits made through the gate, in the direction opposite
to that defined by parameter GD, since the last time the alarm counter was reset (command
CR).
During normal operation, the current value of this parameter can be seen on the display if the
. or
key is pressed
RE
Alarm reset -
C
ATTENTION!
The metal detector will operate under manual reset only during a programming
session and with the reset mode set on "manual" (see the
RM
function). Outside of the
programming session, the device will operate under automatic reset.
If the
RE
command has not been authorised for the user environment, the mechanism will
operate under automatic reset during a programming session at user level.
RM
Alarm reset
mode
M, A
C/R
M Mode
: corresponds to manual reset via command
RE
. The alarm is kept in memory until
the RE command is executed. (N.B.: any reset button that might be connected to terminal
PP1 will not have any effect)
A Mode
: corresponds to automatic reset:: the alarm stops shortly after the transit through the
transducer is completed.
AA
Indication of
the size of
the metal
mass
detected
0-4 R
Displays the size of the metal mass detected (during an alarm in manual reset mode, see
RM
function). 5 different values can be adjusted, ranging from:
• 0 (no alarm)
• 1 (small mass)
•
•
• 4 (large mass).
Status reading does not reset the Metal Detector alarm.
HE
HELP
-
R
This selects a display of the meaning of the programming codes. The read-out will give the
correspondence table (function – function code)
The * character indicates that the command is enabled at user level (see the
UP
command).
PE
Programmin
g end
-
C
This command will be executed automatically if no commands are entered for a period of 2
minutes.
PT
Parameter
table
-
R
Displays the values of the operating parameters. The serial number of the device appears at
the top.
The character * indicates that the command is enabled at user level (see command
UP
).
SC
Self-
diagnosis
R
Displays the status of the Metal Detector. When operating properly, this message appears:
OK
System working perfectly
If one of the device’s components is faulty, a message will be displayed (in descending order
of priority). For more details see the “Maintenance” section.
N.B.:
The SC command can only be executed in remote programming. The self-diagnosis
device is permanently active, and any indication of malfunction is given automatically on the
display.