HI-PE multi-zone --- Rev.
FI 050 GB 60K10 v2_1
8
OPTIONS
Transit counter
Two photocells fitted into the antennae allow counting of transits, alarms and percentage of alarms.
TX
Fig. I-5a Photocells
RX
Fig. I-5b Reflectors
RX
TX
Emergency batteries
Two 12V-0,8Ah batteries built into the antenna switch in automatically and allow about 30 minutes of
independent operation in the event of a mains failure. The batteries recharge automatically when the metal
detector is connected to the AC power supply and switched on.
Use of the emergency batteries is signalled by a flashing letter "
B
" on the electronics unit display. Recharge
time is about 8 hours.
The batteries (2) are housed in a compartment located in the upper part of the TX panel and are connected
to the recharging card AB via the connectors (4).
1
cover
2
batteries
(model NP
0.8-12 Yuasa)
3
card
ALP (battery
charger)
4
battery connectors
5
connector for internal
connections
Fig. I-6
4
4
5
1
2
3
2