SOME SAFETY MEASURES 

Important Precautions: 

 CEIL DSP Sine wave Static USP has two Battery terminals coming out from the rear side, an AC 

MCB,  a  DC  MCB,  an  AC output  socket  and  an  AC  Input  socket.    Battery  terminals  are  red  and 

black in colour. The red colour terminal has to be connected to the POSITIVE TERMINAL of the 

battery and black one to the NEGATIVE TERMINAL. 

CAUTION: 

 

Do not reverse the battery connections as it will trip the Battery MCB/ Fuse. 

Ensure  that  the  incoming  phase  (or  line)  is  connected  to  'L',  Neutral  is  connected  to  'N'  and 

earth is connected through OUTPUT socket of the Static UPS. 

General Precautions: 

 

Before  using  the  CEIL  DSP  Sine  wave  Static  UPS  read  all  instructions  and  caution 

markings on the Static UPS, the batteries and all appropriate sections of this Instruction 

manual. 

 

Do not expose CEIL DSP Sine wave Static UPS to any type of chemicals. 

 

Do  not  disassemble  the  CEIL  DSP  Sine  wave  Static  UPS.  Take  it  to  a  qualified  our 

Engineering  Service  Centre  when  service  or  repair  is  required.  Opening  by  unqualified 

person can lead to electrical shock or fire hazard. 

 

To reduce risks of electric shock disconnect all wiring before cleaning. 

WARNING:

  

Avoid  exposing  the  Static  UPS  or  Batteries  to  any  type  of  explosive  gases  in  the  vicinity  as 

batteries generate explosive gases during normal operation. Ensure proper ventilation for the 

battery  compartments.  The  Battery  enclosures  should  be  so  designed  as  to  prevent 

accumulation  and  concentration  of  hydrogen  gas  in  'pockets'  at  the  top  of  the  compartment. 

Vent the battery compartment from the highest point. A sloped lid can also be used to direct 

the flow to the vent opening location. To reduce the risk of battery explosion, strictly follow the 

instructions  of  the  battery  supplier  for  any  equipment  you  intend  to  use  in  the  vicinity  of 

batteries. 

 

Use the correct tools to make AC/DC wiring connections. 

 

Do  not  install  this  CEIL  DSP  Sine  wave  Static  UPS  on  or  near  flammable  materials 

(plywood, chemicals, gasoline etc) 

Summary of Contents for Static UPS System

Page 1: ......

Page 2: ...need help at any time please feel free to contact us we would welcome any queries suggestions from you that will enable us to improve product quality and also offer you better service With best wishes...

Page 3: ...ont Panel 1 Back Panel 2 Display Status 3 Some Safety Measures 4 Concept of Charging 6 Getting Started 7 Installing your Static UPS 8 Operation Installation Diagram 10 Technical Specifications 11 Trou...

Page 4: ...ank connected with it and also to convert Direct Current DC of the Battery Bank to Alternating Current AC for the electrical loads The Battery Bank with the Static UPS acts as a reservoir to ensure co...

Page 5: ...the AC main Utility Power 6 Battery MCB To switch on the DC supply 7 AC Mains For AC mains connection 8 Output For output load connection 9 Battery Terminal Negative Black To connect battery wire blac...

Page 6: ...ttery Volt Mains OK Load Battery Low Protection Battery Low Beeping Output over load Warning Beeping Overload I P MCB Trip I P MCB Trip Beeping O P Short Circuit Protection Short Circuit Beeping UPS o...

Page 7: ...L DSP Sine wave Static UPS Take it to a qualified our Engineering Service Centre when service or repair is required Opening by unqualified person can lead to electrical shock or fire hazard To reduce...

Page 8: ...spark that could cause an explosion Remove personal metal items such as rings bracelets necklace and watches when working with the battery Battery can produce short circuit current high enough to caus...

Page 9: ...to 50 of bulk charging rate i e 4 to 5AMP Taper When the voltage level of battery is 20 more than its rated voltage the taper mode of the charger will be activated which will keep the charging current...

Page 10: ...equipment and other items Important Precaution The output side of the Static UPS AC wiring should never be connected to a generator or incoming utility power This condition is far worse than a short c...

Page 11: ...nnect all AC power c Disconnect all the battery cables DC CABLING Ensure that the ON OFF switch on the front panel of the Static UPS is in the OFF Position before you begin the installation also keep...

Page 12: ...r to it Ensure that all wiring has been installed properly Next turn on the battery bank DC disconnects or connects the proper fuse MCB in line to the battery to complete the battery circuit Put ON OF...

Page 13: ...Installation Diagram For Static UPS...

Page 14: ...Technical Specifications...

Page 15: ...Trouble Shooting...

Page 16: ...Static UPS Test Report Tested by Inspected by Date Date Sign Sign...

Page 17: ...it Mains Voltage Mains N E Voltage Mains Frequency Back Up System DG Set Frequency Hz Output Side Rating of Output Circuit Breaker AMP O P Wire Thickness sq mm Output Voltage Volts Output N E Voltage...

Page 18: ...Volt AC Output current at full load AMP Output frequency 50HZ 1 0 stable Output wave form Sinewave Static UPS front panel ON Off switch and LCD display Rear panel Mains MCB Battery MCB Bypass switch I...

Page 19: ......

Reviews: