CAUTION: 

 

The  CEIL  DSP  Sine  wave  Static  UPS  should  be  connected  to  grounded,  permanent  wiring 

systems. 

Personal Precautions: 

 

A person should be within the range of your voice so as to come to your aid when you 

work near batteries 

 

Keep  plenty  of  fresh  water  and  soap  nearby  in  the  event  that  battery  acid  comes  in 

contact with skin, clothing or eyes. 

 

Avoid touching eyes while working near batteries; Wash your hands when work done. 

 

If battery acid comes in contact with skin or clothing wash immediately with soap and 

water. If acid enters eyes immediately flood eyes with running cool water for at least 15 

minutes and get medical attention immediately. 

 

Baking soda neutralizes battery electrolyte. 

 

NEVER smoke or allow spark or a flame in the vicinity of the battery. 

 

Be  extra  cautious  when  working  with  metal  tools  on  and  around  batteries.  It  could 

short-circuit  the  batteries  or  other  electrical  parts,  producing  a  spark  that  could  cause 

an explosion. 

 

Remove  personal  metal  items  such  as  rings,  bracelets,  necklace  and  watches  when 

working  with  the  battery.  Battery  can  produce  short-circuit  current  high  enough  to 

cause severe burns. 

 

Never attempt to charge a frozen battery. 

 

Before touching the Battery terminal makes sure that the Static UPS front switch is OFF 

and AC mains to the Static UPS is also OFF. 

 

If it is necessary to remove any battery, always remove the grounded terminal from the 

battery first. Make sure all the accessories are off, so as not to cause arcing. 

 

Be sure that the area around the battery is well ventilated. 

 

Clean battery terminals. Be careful not to allow corrosion to come in contact with eyes. 

 

Study  specific  precautions  and  recommended  rates  of  charge  of  all  battery 

manufacturers. 

 

Add only distilled water in each cell until battery acid reaches level specified by battery 

manufacturer.  This  helps  purge  excessive  gas  from  cells.  Do  not  overfill.  For  a  battery 

without caps, carefully follow manufacturer's recharging instructions. 

Exide India, is not responsible for any kind of battery related problems. 

 

Summary of Contents for Static UPS System

Page 1: ......

Page 2: ...need help at any time please feel free to contact us we would welcome any queries suggestions from you that will enable us to improve product quality and also offer you better service With best wishes...

Page 3: ...ont Panel 1 Back Panel 2 Display Status 3 Some Safety Measures 4 Concept of Charging 6 Getting Started 7 Installing your Static UPS 8 Operation Installation Diagram 10 Technical Specifications 11 Trou...

Page 4: ...ank connected with it and also to convert Direct Current DC of the Battery Bank to Alternating Current AC for the electrical loads The Battery Bank with the Static UPS acts as a reservoir to ensure co...

Page 5: ...the AC main Utility Power 6 Battery MCB To switch on the DC supply 7 AC Mains For AC mains connection 8 Output For output load connection 9 Battery Terminal Negative Black To connect battery wire blac...

Page 6: ...ttery Volt Mains OK Load Battery Low Protection Battery Low Beeping Output over load Warning Beeping Overload I P MCB Trip I P MCB Trip Beeping O P Short Circuit Protection Short Circuit Beeping UPS o...

Page 7: ...L DSP Sine wave Static UPS Take it to a qualified our Engineering Service Centre when service or repair is required Opening by unqualified person can lead to electrical shock or fire hazard To reduce...

Page 8: ...spark that could cause an explosion Remove personal metal items such as rings bracelets necklace and watches when working with the battery Battery can produce short circuit current high enough to caus...

Page 9: ...to 50 of bulk charging rate i e 4 to 5AMP Taper When the voltage level of battery is 20 more than its rated voltage the taper mode of the charger will be activated which will keep the charging current...

Page 10: ...equipment and other items Important Precaution The output side of the Static UPS AC wiring should never be connected to a generator or incoming utility power This condition is far worse than a short c...

Page 11: ...nnect all AC power c Disconnect all the battery cables DC CABLING Ensure that the ON OFF switch on the front panel of the Static UPS is in the OFF Position before you begin the installation also keep...

Page 12: ...r to it Ensure that all wiring has been installed properly Next turn on the battery bank DC disconnects or connects the proper fuse MCB in line to the battery to complete the battery circuit Put ON OF...

Page 13: ...Installation Diagram For Static UPS...

Page 14: ...Technical Specifications...

Page 15: ...Trouble Shooting...

Page 16: ...Static UPS Test Report Tested by Inspected by Date Date Sign Sign...

Page 17: ...it Mains Voltage Mains N E Voltage Mains Frequency Back Up System DG Set Frequency Hz Output Side Rating of Output Circuit Breaker AMP O P Wire Thickness sq mm Output Voltage Volts Output N E Voltage...

Page 18: ...Volt AC Output current at full load AMP Output frequency 50HZ 1 0 stable Output wave form Sinewave Static UPS front panel ON Off switch and LCD display Rear panel Mains MCB Battery MCB Bypass switch I...

Page 19: ......

Reviews: