The receiver has signalization  of non current flow through optocoupler.  It is indicated by the red LED RX on front panel of the

converter. This LED lit when it is:

- not connect transmitter to receiver,

- wrong connection of transmitter to receiver,

- broken connection of transmitter to receiver.

The diagram is shown on figure below.

Fig. 2. Diagram of the transmitter & receiver ADA-1021 Current Loop

2.5. ISOLATION

Converter ADA-1021 has 3-way galvanic isolation on level 1kV= or 3kV=, depend on version described  in section 

VERSIONS

.

Fig. 3. Isolation structure

3. INSTALACJA

This chapter will show how to connect ADA-1021 to PC, Current Loop bus, RS232 bus and power supply and how to use it.

In the purpose of minimization of disruptions from environment is being recommended to:

apply multipair type shielded cables,  which shield can be connected to the earthing on one end of the cable,

arrange signal cables in the distance not shorter than 25 cm from powering cables,

apply cable of adequate cross-section due to voltage drops for converter powering, 

use Interference suppression filters for power supply converters that are installed within a single object.

not supply converter from power circuit device that generates large impulse interference such as transmitters, contactors, 

3.1. ASSEMBLING

The ADA-1021 enclosure is adapted to assembly on TS-35 (DIN35) rail. To instal converter should the upper part of casing hang

hooks on the rail, than push the lower part until to hearing characteristic "Click" sound.

3.2. CONNECTION OF DEVICES WITH  RS232 PORT 

Fig. 4. RS232 interface signals of DB-9F (female) connector

5

ADA-1021

4 DSR not use 

The Signals looped on the converter :
1. DTR – DSR – DCD
2. RTS - CTS

2 TX

5 GND

Not use  RI 9

Not use  RTS 8

Not use  CTS 7

Not use  DTR 6

3 RX

1 DCD not use 

Power Supply

10 - 30VDC

RS232

Current Loop

3-WAY ISOLATION

I2 -

I= 0 / 20mA

I

I2 +

RX-

Passive Receiver

I2 – Receiver's 

Current source

RX+

TX-

I= 0 / 20mA

TX+

Passive Transmitter

I1 -

I= 0 / 20mA

I

I1 +

I1 – Transmitter's 

Current source

Summary of Contents for ADA-1021

Page 1: ...User manual ADA 1021 RS 232 to Current Loop Converter 1 io_ada 1021_v1 02_en Copyright 2001 2017 CEL MAR sp j ADA 1021...

Page 2: ...ECTION OF DEVICES WITH RS232 PORT DCE TYPE MODEM 6 3 3 CONNECTION OF CURRENT LOOP DEVICES 7 3 3 1 CONNECTION TO DEVICE WITH PASSIVE TRANSMITTER PASSIVE RECEIVER 7 3 3 2 CONNECTION TO DEVICE WITH ACTIV...

Page 3: ...ps and the like Complete disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This...

Page 4: ...converter RTS signal is looped with CTS inside the converter and DTR with DSR and DCD Others signals are not connected If it is not needed looping the above signals can be unsolder the RTS or DTR in t...

Page 5: ...cables in the distance not shorter than 25 cm from powering cables apply cable of adequate cross section due to voltage drops for converter powering use Interference suppression filters for power supp...

Page 6: ...lable in CEL MAR offer Example connection is shown below Fig 6 Connection to device with RS232 type DCE 6 ADA 1021 RxD 2 TxD 3 DTR 4 DSR 6 RTS 7 CTS 8 PC SG 5 RS232 DTE DB 9M ADA 1021 Current Loop Vss...

Page 7: ...with active transmitter and active receiver to ADA 1021 7 ADA 1021 ADA 1021 V V Power Tx Tx Rx Rx Current Loop Device I1 I1 I2 I2 Rx Current Loop connector Tx Tx Rx V V Active Transmitter Active Recei...

Page 8: ...21 ADA 1021 Active transmitter Power Tx Tx Rx Rx Current Loop Device I1 I1 I2 I2 Rx Passive receiver Tx Tx Rx Current Loop connector Current Loop connector V V V V Passive Receiver Active Transmitter...

Page 9: ...RTS 7 CTS 8 PC SG 5 RS232 DTE DB 9M ADA 1020 Current Loop Vss Vss Power Supply RS232 DCE DB 9F CTS 7 RTS 8 GND 5 V V Tx 2 Rx 3 DSR 4 DTR 6 2 3 4 6 7 8 5 CAB DB 9F DB9M S 1 8m cable Socked DB 9F 2 3 4...

Page 10: ...PWR Signalization of power supply RX Signalization of data receiving by ADA 1021 from Current Loop TX Signalization of data transmission from ADA 1021 converter through Current Loop ATTENTION AT BAUD...

Page 11: ...ow LED data transmission through Current Loop interface Electrical Parameters Power requirements 10 24 30 V DC Power cable Recommended length of power cable 3m Power 3W Protection from reverse power p...

Page 12: ...transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you p...

Reviews: