background image

8. VERSIONS

ADA-1040D - 

-

Order example:
Product Symbol: 

ADA-1040D-23-3

23

 - galvanic isolation: 1kV= 3-way,

3

 - cover without inlets, plug-in screw terminal block

Galvanic isolation:

1kV= 2-way

2

1kV= 3-way

23

3kV= 2-way

3

3kV= 3-way

33

Terminal & Terminal Cover:

Cover without inlets, screw terminal block

1

Cover with inlets, screw terminal block

2

Cover without inlets, plug-in screw terminal block

3

9. SPECIFICATION

TECHNICAL DATA

Transmission Parameters

Interface

RS-232

RS-485/RS-422

Connector

DSUB-9 Female

Screw terminal block - max. Ø 2,5mm

2

Max. Line length

15 m

1200 m

Max. number of connected device

1

1

Transmission line

DB9F/DB9M multicore cable  9x0,34 
shielded or  9-pair twisted cable, UTP 
9x2x0,5 (24AWG) shield inside large 
interferences STP 9x2x0,5 (24AWG).

1-pair or 2-pair twisted cable, UTP 
Nx2x0,5 (24AWG), shield inside large 
interferences STP Nx2x0,5 (24AWG)

Standards

EIA-232, CCITT V.24

EIA-485, CCITT V.11

Max. baud rate

230,4 kbps

Transmission type

Asynchronous full duplex, half duplex.

Optical Signalization

PWD – green LED power supply,

RX - red LED data receiving on RS485/RS422,

TX - yellow LED data transmission via RS485/RS422.

Electrical Parameters

Power requirements

10 - 24 – 30 V DC

Power Cable

Recommended length of power cable – up to 3m

Power

<2W

Protection from reverse power polarization

YES

Galvanic Isolation

1kVDC or 3kVDC - between power circuit and RS-232 signal line

Optoisolation 

3kV - between signals lines RS-232 and RS-485 

Electromagnetic compatibility

Resistance to disruptions according to the standard PN-EN 55024.
Emission of disruptions according to the standard PN-EN 55022.

Safety requiring

According to the PN-EN60950 norm.

Environment

Commercial and light industrial.

Environmental Parameters

Ambient temperature

-30 ÷ 60°C

Relative air humidity

5 ÷ 95% - non-condensing

External Storage Temperature

 -40 ÷ +70°C

Casing

Dimensions

53 x 90 x 62 mm

Material

PC/ABS

Degree of casing protection

IP40

Degree of terminal protection

IP20

Weight

0,10 kg

13

ADA-1040D

Summary of Contents for ADA-1040D

Page 1: ...User manual ADA 1040D RS 232 to RS 485 4W RS 422 digital converter 1 io_ada 1040d_v1 11_en Copyright 2001 2020 CEL MAR sp j ADA 1040D...

Page 2: ...7 4 3 1 GND TERMINAL CONNECTION 7 4 3 2 LINE TERMINATION Rt 7 4 3 3 EXAMPLE CONNECTION OF CONVERTER AS THE EXTENSION PORT RS232 PC 8 4 4 POWER SUPPLY CONNECTION 8 5 ACTIVATION 8 5 1 TROUBLESHOOTING 8...

Page 3: ...assembly or disassembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medic...

Page 4: ...bus is made by the use of 2 pairs twisted cable The converter has the connection control for testing the correctness connection of RS485 4W bus with him ADA 1040D is equipped with DSUB 9 female conne...

Page 5: ...s of using the converter as extender of RS232 PC port Fig 3 Operating principle of ADA1040D Fig 4 Example connection of a cash register with RS232 interface to PC 1200 m away 5 ADA 1040D Cash register...

Page 6: ...MBLING ADA 1040D converter case is adapted to assembly on TS 35 DIN35 rail To install converter should mount device on the rail upper part of the case then press bottom part to hearing characteristic...

Page 7: ...tallation signals grounds of other devices 4 3 2 LINE TERMINATION Rt The application of Line Termination terminator Rt 120 W ohms will reduce electrical reflection in data line at high baud rate It is...

Page 8: ...onnection is there no break or short circuit of the bus is there connected the converter on the other side of the bus to power supply 10 30VDC stabilized are there set the same baud rate on RS485 4W R...

Page 9: ...riate settings by the use a small flat screwdriver All available adjusting the SW1 switch are shown in table below If there are additional question please contact with technical department 48 41 362 1...

Page 10: ...smission parameters to the length of RS485 422 bus Available baud rates kbps 0 3 0 6 1 2 1 8 2 4 4 8 7 2 9 6 14 4 19 2 28 8 38 4 57 6 76 8 115 2 230 4 ATTENTION IN BOTH CONVERTERS CREATING CONNECTION...

Page 11: ...onverter ports After finishing the diagnostics the SW1 microswitch should be set to the run mode as shown in the table below SW1 1 SW1 2 OFF OFF The yellow LED located near the SW1 will turn off 6 4 F...

Page 12: ...t the power and after while connect again After that will be loaded the factory default setting Parameters are as follows RS232 RS485 4W 422 Baud rate 9600 bps Baud rate 19200 bps 8 data bits 8 data b...

Page 13: ...EIA 485 CCITT V 11 Max baud rate 230 4 kbps Transmission type Asynchronous full duplex half duplex Optical Signalization PWD green LED power supply RX red LED data receiving on RS485 RS422 TX yellow L...

Page 14: ...According to standards DIN EN50022 DIN EN43880 Location during work Free Mounting Rail mounting according to DIN35 standard TS35 14 ADA 1040D...

Page 15: ...15 ADA 1040D...

Page 16: ...transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you pr...