background image

1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION 

ADA-1040D 

converter is covered by a two year warranty from date of sale.  In case of being damaged it will be repair or the damaged

component   will   be   replace.  The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption  or   any
unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be
repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so
as not to be exposed to trampling, attaching, or pulling out of the circuit. 
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 
Do not carry out the assembly or disassembly of the device if it is enabled. This may result to short circuit and damage the device.
The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility Directive 

EMC 2014/30/WE.

 

Declaration of Conformity is delivered with purchased converter.

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

Converter ADA-1040D does not require the servicing and maintenance.
Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

support@cel-mar.pl

.

1.6. PACK CONTENTS

Converter ADA-1040D, User Manual, CE declaration, Line terminators 120

W

  (2 pcs.), CD-ROM with ADAConfig software.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Signals conversion Tx, Rx, RTS, CTS, DTR, DSR of RS232 interface to RS485(4W) / RS422,

Conversion data format and baud rate on RS485/RS422 and RS232 converter interfaces,

Operating on 4-wire bus in Point-to-Point mode,

Correctness connection control of RS485 /422 bus,

Automatic data flow control (transmitter/receiver) on RS485 bus,

Baud rate on  RS232  and  RS485/422  interfaces  ( bps):  300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 28800,
38400, 57600, 76800, 115200, 230400, 

Data format set on RS232 & RS485/RS422 interfaces: data bit: 5, 6, 7, 8; parity: None, Odd, Even; number of stop bits: 1, 2,

Transparent for all protocols which data format is compatible with the following specifications: MODBUS, DNP, PROFIBUS and
other,

Power supply 10 - 30 VDC stable min. 2W,

Implemented protection against power supply reverse connection,

~3kV= optoizolation in signal channel between RS232 and RS485/422 interfaces,

1kV= or 3kV= galvanic isolation between RS232 & RS485/422 interfaces and power supply (depend on version),

Implemented short circuit protection and over-voltage protection on RS485 / RS422 bus,

Connection RS485/RS422 network and power supply via screw terminal block 2.5 mm

.

DB-9F connector for cable connection of RS232 interface to PC, controller etc. 

Cover compatible with DIN 43880 standard– mounting in typical electro-installation unit,

3

ADA-1040D

Summary of Contents for ADA-1040D

Page 1: ...User manual ADA 1040D RS 232 to RS 485 4W RS 422 digital converter 1 io_ada 1040d_v1 11_en Copyright 2001 2020 CEL MAR sp j ADA 1040D...

Page 2: ...7 4 3 1 GND TERMINAL CONNECTION 7 4 3 2 LINE TERMINATION Rt 7 4 3 3 EXAMPLE CONNECTION OF CONVERTER AS THE EXTENSION PORT RS232 PC 8 4 4 POWER SUPPLY CONNECTION 8 5 ACTIVATION 8 5 1 TROUBLESHOOTING 8...

Page 3: ...assembly or disassembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medic...

Page 4: ...bus is made by the use of 2 pairs twisted cable The converter has the connection control for testing the correctness connection of RS485 4W bus with him ADA 1040D is equipped with DSUB 9 female conne...

Page 5: ...s of using the converter as extender of RS232 PC port Fig 3 Operating principle of ADA1040D Fig 4 Example connection of a cash register with RS232 interface to PC 1200 m away 5 ADA 1040D Cash register...

Page 6: ...MBLING ADA 1040D converter case is adapted to assembly on TS 35 DIN35 rail To install converter should mount device on the rail upper part of the case then press bottom part to hearing characteristic...

Page 7: ...tallation signals grounds of other devices 4 3 2 LINE TERMINATION Rt The application of Line Termination terminator Rt 120 W ohms will reduce electrical reflection in data line at high baud rate It is...

Page 8: ...onnection is there no break or short circuit of the bus is there connected the converter on the other side of the bus to power supply 10 30VDC stabilized are there set the same baud rate on RS485 4W R...

Page 9: ...riate settings by the use a small flat screwdriver All available adjusting the SW1 switch are shown in table below If there are additional question please contact with technical department 48 41 362 1...

Page 10: ...smission parameters to the length of RS485 422 bus Available baud rates kbps 0 3 0 6 1 2 1 8 2 4 4 8 7 2 9 6 14 4 19 2 28 8 38 4 57 6 76 8 115 2 230 4 ATTENTION IN BOTH CONVERTERS CREATING CONNECTION...

Page 11: ...onverter ports After finishing the diagnostics the SW1 microswitch should be set to the run mode as shown in the table below SW1 1 SW1 2 OFF OFF The yellow LED located near the SW1 will turn off 6 4 F...

Page 12: ...t the power and after while connect again After that will be loaded the factory default setting Parameters are as follows RS232 RS485 4W 422 Baud rate 9600 bps Baud rate 19200 bps 8 data bits 8 data b...

Page 13: ...EIA 485 CCITT V 11 Max baud rate 230 4 kbps Transmission type Asynchronous full duplex half duplex Optical Signalization PWD green LED power supply RX red LED data receiving on RS485 RS422 TX yellow L...

Page 14: ...According to standards DIN EN50022 DIN EN43880 Location during work Free Mounting Rail mounting according to DIN35 standard TS35 14 ADA 1040D...

Page 15: ...15 ADA 1040D...

Page 16: ...transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you pr...

Reviews: