1. GENERAL INFORMATION
Thank you for purchasing of
CEL-MAR Company
product. This product has been completely tested and is covered by a two year
warranty on parts and operation from date of sale.
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.
1.1. GUARANTEE INFORMATION
ADA-13020
converter is covered by a two year warranty from date of sale. In case of being damaged it will be repair or the damaged
component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any
unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be
repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the
CEL-MAR Company.
CEL-MAR Company
under no circumstances won't be responsible for ensuing damage from improper using the product or as a result
of random causes: the lightning discharge, the flood, the fire and the like.
CEL-MAR Company
is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing
from using or the impossibility of using this product.
In specific cases
CEL-MAR Company
discontinue all warranties and in particular do not follow the user manual and do not accept
terms of warranty by the user.
1.2. GENERAL CONDITIONS FOR SAFE USE
The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged so
as not to be exposed to trampling, attaching, or pulling out of the circuit.
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage.
Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.
The device can not be used for applications that determine human life and health (eg. Medical).
1.3. CE LABEL
The CE symbol on the device CEL-MAR means compatibility with electromagnetic compatibility Electromagnetic
Compatibility Directive
EMC 2014/30/WE.
Declaration of Conformity is available by contact with Technical Service
(email: support@cel-mar.pl; phone: +48 41 362-12-46).
1.4. ENVIRONMENTAL PRESERVATION
This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)
1.5. SERVICE AND MAINTENANCE
The ADA-13020 converter doesn't require the periodic conservation.
Technical support at the number: +48 41 362-12-46 in 8.00-16.00, from Monday to Friday.
1.6. PACK CONTENTS
The converter is delivered with the user manual and CD-ROM with ADANet software.
2. PRODUCT INFORMATION
2.1. PROPERTIES
●
Operate on ETHERNET network - according to IEEE 802.3 specification,
●
10/100BaseT physical layer,
●
Baud rate 10/100Mbps (auto-sensing),
●
Full or half duplex (auto-sensing) operating mode,
●
Protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP,
●
WWW sever implemented for converter configuration,,
●
Configuration of net services according to user personal setting,
●
Static or dynamic IP address (added by DHCP verver),
●
Diagnostics of serial and network port,
●
Encoded transmission: DES (56-bit), 3DES (168-bit), AES (128/256-bit),
●
Operating modes: virtual serial port, serial bridge TCP, serial bridge UDP, TCP sockets, UDP sockets,
●
Operating on 4 wire line according to Current Loop specification,
●
Current Loop baud rates (bps): 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400,
●
Current Loop data format - Number of data bits: 5, 6, 7, 8; Parity checking: None, Odd, Even, Constantly 1, Constantly 0; Stop Bits:
1, 2,
●
Transparent for all protocols, which the data format is compatible with the above specifications of Current Loop interface eg
MODBUS DNP, PROFIBUS and other,
●
Power supply 10 - 30 VDC stable min. 3W,
4
ADA-13020