After saving the UDP Sockets profile, will open section
UDP Server Settings
with operating parameters like on picture below. Set
access to UDP server on e.g. 2101 port. Then select
Automatically send serial data
in section
UDP Client Settings
, this
automatically send received data by the use UDP client service to the SLAVE device connected to LAN/WAN through e.g. ADA-13021
ADA-13020, ADA-13028L, ADA-13040MG, ADA-13110, ADA-14040, ADA-14040.
On lists
Send data to the following network services
are addresses of network devices and ports to which will be send data. In
field:
–
Description
- enter e.g. location of the converter and SLAVE device,
–
Send To
- enter IP address of e.g. converter, connected to SLAVE device,
–
UDP Port
- enter the number of port on which is working UDP Server of converter connected to SLAVE device
In the section
Send data under any of the following conditions
is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for MASTER device, press
[Apply]
.
Fig. 21. Example configuration of the UDP server&client on converter connected to MASTER device
5.2.2.1.3.2. UDP CLIENT & SERVER CONFIGURATION IN CASE OF SLAVE DEVICE
Set operating parameters of UDP server on the converter connected to SLAVE device eg. like on picture below. Set an access to UDP
server on e.g. 2101 port. Then select
Automatically send serial data
in section
UDP Client Settings
, this automatically send
received data by the use UDP client service to the MASTER device connected to LAN / WAN through e.g. ADA-13020, ADA-
13028L, ADA-13040MG, ADA-13110, ADA14040, ADA-14040.
On lists
Send data to the following network services
are addresses of network devices and ports to which will be send data. In
field:
–
Description
- enter e.g. location of the converter and MASTER device,
–
Send To
- enter IP address of converter connected to MASTER device,
–
UDP Port
- enter the number of port on which is working UDP Server of converter connected to MASTER device
In the section
Send data under any of the following conditions
is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for SLAVE device, press
[Apply]
.