10. SPECIFICATION

TECHNICAL DATA

Transmission Parameters

Interface

ETHERNET

Current Loop CLO

 

Connector

RJ45

Screw terminal, wire diameter max

2,5mm

2

.

Line length

LAN up to 150 m

Depend on baud rate up to few hundred

meters

Max. number of connected devices

Depend on addressing type setting in the

network

2 point-to-point or 15 in Current Loop

CLO network

Max. baud rate

10/100 Mbit/s

19,2 kbps (depend on length of Current

Loop CLO line)

Transmission line

4-pair twisted cable, UTP 
4x2x0,5(24AWG), shield inside large 
interferences (STP 4x2x0,5(24AWG)).

2-pair twisted cable, 24AWG, shield 
inside large interferences 

Standards

IEEE 802.3

0-20mA /12VDC, 0-20mA /24VDC

Transmission type 

Asynchronism half duplex or full duplex,

Optical Signalization

PWR – green LED power supply,

RX - red LED data receiving from Current Loop CLO side,

TX - yellow LED data transmission through Current Loop CLO interface.

Electrical Parameters

Power requirements

10 - 24 – 30 V DC

Power Cable

Recommended length of  power cable – up to 3m

Power

3W

Protection from reverse power polarization

YES

Galvanic Isolation

1kV= or 3kV= (between power circuit and ETHERNET signal line)
1kV= or 3kV= (between power circuit and Current Loop CLO signal line)

Optoisolation

~3kV= (between signal lines Current Loop and ETHERNET)

Electromagnetic compatibility

Resistance to disruptions according to the standard PN-EN 55024.
Emission of disruptions according to the standard PN-EN 55022.

Safety requiring

According to the PN-EN60950 norm.

Environment

Commercial and light industrial.

Environmental Parameters

Operating temperature

-30 ÷ 60°C

Humidity

5 ÷ 95% - non-condensing

Storage temperature

-40 ÷ 70°C

Casing

Dimensions

53mm x 90mm x 62mm

Material

PC/ABS

Degree of casing protection

IP40

Degree of terminal protection

IP20

Weight

0,10 kg

According to standards

DIN EN50022, DIN EN43880

Location during work

Free

Mounting method

On the rail compliant with DIN35 / TS35 standard.

26

ADA-13028L

Summary of Contents for ADA-13028L

Page 1: ...User manual ADA 13028L ETHERNET to Current Loop CLO Converter 1 io_ada 13028l_v 1 13_en ADA 13028L Copyright 2001 2020 CEL MAR sp j...

Page 2: ...ATION AND MANAGEMENT BY THE USE OF INTERNET BROWSER 15 5 2 1 NETWORK SETTING CONFIGURATION 15 5 2 2 SERIAL PORT CONFIGURATION 16 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION OPERATING MODE 16 5 2 2 1 1 R...

Page 3: ...7 FACTORY DEFAULT 25 8 TROUBLESHOOTING 25 9 VERSIONS 25 10 SPECIFICATION 26 3 ADA 13028L...

Page 4: ...ing circuit Do not take the installation or device disassembly if it is turn on It can lead to the electric short circuit and damaging the device The device can not be used for applications that deter...

Page 5: ...he connection you should use external lightning conductors e g typical protection a telephone line We provide with the converter drivers for Windows and Linux operating systems In the operating system...

Page 6: ...ng on one end of the cable lay signal cables at a distance not less than 25 cm from power cables use suitable diameter cable for power supply on account of voltage drop use the interference eliminator...

Page 7: ...ace of converter are implemented two LED s Fig 2 Green ACT signaling state of sending or receiving data Orange LINK signaling active network connection ADA 13028L converter in the ETHERNET network can...

Page 8: ...r Real Port mode functioning via switch or Hub for LAN network Fig 6 Connection for operating in Real Port mode for WAN network 8 ADA 13028L Devices with Current Loop CLO interface Computer with a net...

Page 9: ...NVERTER Current Loop interface is available on screw terminal block with descriptions CLO CLO Rd Rd and CLO terminals is use for connection of additional resistor in case of setting the sensitivity of...

Page 10: ...interface to ADA 13028L 10 ADA 13028L Device with PASSIVE CLO interface CLO terminal V V Power ETHERNET connector V V CLO CLO ADA 13028L ACTIVE CLO interface CLO terminal V V Power V V Current Loop RJ...

Page 11: ...eter with CLO interface IEC 62056 21 to ADA 13028L 1 1 1 A 2 3 Fig 10a Example of connecting energy meter with CLO interface to ADA 13028L 1 1 1 A 2 3 11 ADA 13028L Device with CLO interface Current L...

Page 12: ...A 2 3 Fig 10b Example of connecting four energy meter with CLO interface to ADA 13028L 1 1 1 A 2 3 12 ADA 13028L CLO CLO CLO CLO Device no 4 passive CLO interface CLO CLO CLO CLO Rd CLO CLO NC V V RJ...

Page 13: ...Below are described the stages of software installation and network setting configuration of converter 5 1 INITIAL CONFIGURATION USING ADAFINDER SOFTWARE 5 1 1 ADAFINDER INSTALLATION The initial conf...

Page 14: ...Fig 11 Basic network configuration using ADAFinder Fig 12 IP address setting 14 ADA 13028L...

Page 15: ...ow Fig 13 Page for manage and configuration of ADA 13110 converter 5 2 1 NETWORK SETTING CONFIGURATION To make changes of default setting or new configuration of ADA 13028L select on left panel Config...

Page 16: ...erial Port Configuration select Port 1 will open the configuration details page includes Port Profile Settings Basic Serial Settings Advanced Serial Settings 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION...

Page 17: ...5 2 2 1 2 TCP SOCKETS CONFIGURATION Choosing TCP Sockets is configured the serial port of ADA 13028L for direct communication with PC by the use of TCP socked Data sending by application to TCP socked...

Page 18: ...is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client service 5 2 2 1 2 2 THE ENABLE TCP KEEP A...

Page 19: ...ers like on picture below Set access to UDP server on e g 2101 port Then select Automatically send serial data in section UDP Client Settings this automatically send received data by the use UDP clien...

Page 20: ...the following conditions is recommended to set parameters like on picture bellow For saving the configuration of UDP client and server for SLAVE device press Apply Fig 19 Configuration of UDP client...

Page 21: ...entity Settings allows to add name of converter describe the location and add identification number Simple Network Management Protocol Settings SNMP allows to make the configuration of management prot...

Page 22: ...enables upload and delete Web provided by manufacturer Uploaded index htm or index html allows to automatically run the page in the web browser after entering http address ip convertera FS WEB index...

Page 23: ...the installation window will appear press Next 7 will start the searching for converters in the network 8 if no devices were not found press Next 9 should be set in the window Describe the device IP...

Page 24: ...Fig 26 Device view on Windows XP system Fig 27 Configuration of multi port series adapter 24 ADA 13028L...

Page 25: ...nverter form the backup I changed the configuration and the converter isn t functioning 1 Enter in the Internet browser http converter ip address 2 Select the menu Factory Default Settings press Resto...

Page 26: ...Current Loop CLO interface Electrical Parameters Power requirements 10 24 30 V DC Power Cable Recommended length of power cable up to 3m Power 3W Protection from reverse power polarization YES Galvani...

Page 27: ...27 ADA 13028L...

Page 28: ...ransmission converters with interface RS232 RS485 RS422 USB Ethernet Wi Fi Current Loop Fibre Optic Converters and the other Please contact us to tell how you like our products and how we can satisfy...

Reviews: