Fig 16. Selection serial port profile page
5.3.2.1.1. REALPORT (VIRTUAL PORT )
Choosing
RealPort
(Virtual Port, Fig. 16) is configured the serial port of ADA-13040MG, for communication with virtual port COM of
computer. Press [
Apply
] for save. After installing drivers of virtual port COM in operating system, data sending by application to this
port are transferred through WLAN/WAN to ADA-13040MG converter and are present on his serial port. The drivers
RealPort
installation is presented in chapter 6. Normally
RealPort
service allows for one connection through WLAN/WAN, between computer
and server port.
Connection from other computers to the server will be not taken, what will cause the error message.
5.3.2.1.2. TCP SOCKETS
Choosing
TCP Sockets
is configured the serial port of ADA-13040MG, for communication with PC by the use of TCP socked. Data
sending by application to TCP socked are transferred through network. to ADA-13040MG converter and are present on his serial port
Press [
Apply
] for save.
15
ADA-13040MG