Fig 30. Example configuration of multi-port serial adapter
7. FACTORY DEFAULT
Parameter
Value
User name
root
Password
dbps
IP address
Obtain an IP address automatically using DHCP
Operating mode
RealPort
Bout rate[bits/sec]
9600
Number of data bits
8
Parity Control
no
Number of stop bits
1
Flow Control
no
8. PROBLEMS
Problem
Solution
I forgot the password
Restoring Default Settings according to steps below:
1. Power OFF the ADA-13040MG
2. Remove the cover of Serial Server Wi-Fi connector,
3. Press RESET “RST” and holding the button turn the power on of ADA-13040MG,
4. Release the button and after 20 sec. the Serial Server will start with Default Settings (sec. 7).
Restoring Default Settings deletes existing configuration and the proper configuration should be loaded
form the backup.
I changed the
configuration and the
converter isn't
functioning.
1. Enter in the Internet browser
http://address-ip-
server,
2. From menu
[Factory Default Settings]
press
[Restore]
.
26
ADA-13040MG