7. FACTORY DEFAULT
Parameter
Value
User name
root
Password
dbps
IP address
Obtain an IP address automatically using DHCP
Operating mode
RealPort
Bout rate[bits/sec]
9600
Number of data bits
8
Parity Control
no
Number of stop bits
1
Flow Control
no
8. TROUBLESHOOTING
Problem
Solution
I forgot the password
Restoring Default Settings according to steps below:
1. Disconnect the power of the converter,
2. Remove the cover of ETHERNET connector,
3. Press RESET “RST” and holding the button, connect the power of the converter,
4. Release the button after 20 sec. when the converter will start with default settings.
Restoring Default Settings deletes existing configuration and the proper configuration
should be loaded to the converter from the backup.
I changed the configuration and the
converter isn't functioning.
1. Enter in the Internet browser
http://converter
-ip-
address
,
2. Select the menu
[Factory Default Settings]
press
[Restore]
.
9. VERSIONS
ADA-13110 -
-
-
Order example:
Product Symbol:
ADA-13110-1-2-3
1
– basic version of electronic,
2
–
1kV= galvanic isolation, from the power supply,
3
–
cover without inlets, plug-in screw terminal block.
Electronic versions:
Basic
1
Galvanic isolation:
1kV= from the power supply
2
3kV= from the power supply
3
1kV= 3-way
23
3kV= 3-way
33
Terminal & Terminal Cover:
Cover without inlets, screw terminal block
1
Cover with inlets, screw terminal block
2
Cover without inlets, plug-in screw terminal block
3
Isolation from the power supply allows transmitting signals: Tx, Rx, RTS, CTS, DTR, DSR, DCD of RS232 interface.
3-way isolation allows transmitting signals: Tx, Rx, RTS of RS232 interface.
22
ADA-13110