1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION 

ADA-13110 

converter is covered by a two year warranty from date of sale.

 

 In case of being damaged it will be repair or the damaged

component   will   be   replace.   The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption   or   any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired or replaced. 
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company 

is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases 

CEL-MAR Company 

discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity  is   available   by   contact   with   Technical   Service

(email: support@cel-mar.pl; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

ADA-13110 converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

support@cel-mar.pl

.

1.6. PACK CONTENTS

The converter is delivered with: User Manual, ADANet software CD.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Functioning on ETHERNET network- IEEE 802.3 standard, 

10/100BaseT physical layer,

Connection Ethernet networks via RJ45 connector

Baud rate 10/100Mbps (auto-sensing),

Full or half duplex (auto-sensing) operates mode,

Protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP,

WWW sever implemented for converter configuration,

Configuration of net services according to user personal setting,

Static or dynamic IP address (added by DHCP server),

Diagnostics of serial and network port,

Encoded transmission: DES (56-bit), 3DES (168-bit), AES (128/256-bit),

Functioning in modes: virtual serial port, TCP serial bridge, UDP serial bridge, TCP sockets, UDP sockets,

RS232 interface signals: Rx, Tx, RTS, CTS, DTR, DSR, DCD,

RS232 baud rate  ( bps):  50, 75, 110, 134, 150, 200,  300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400,

57600, 115200, 230400,

RS232 data format - Number of data bits: 5, 6, 7, 8; Parity checking: None, Odd, Even, Constantly 1, Constantly 0; Stop Bits: 1, 2, 

Transparent for all protocols, which the data format is compatible with the above specifications of RS232 interface e.g. MODBUS,

DNP, PROFIBUS and other,

3

ADA-13110

Summary of Contents for ADA-13110

Page 1: ...User manual ADA 13110 RS232 to ETHERNET converter 1 io_ada 13110_v 1 12_en ADA 13110 Copyright 2001 2017 CEL MAR sp j...

Page 2: ...RT PROFILE CONFIGURATION OPERATING MODE 12 5 2 2 1 1 REALPORT VIRTUAL PORT CONFIGURATION 13 5 2 2 1 2 TCP SOCKETS CONFIGURATION 13 5 2 2 1 2 1 TCP SERVER CLIENT CONFIGURATION 13 5 2 2 1 2 2 THE ENABLE...

Page 3: ...pply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the d...

Page 4: ...was provided from the power pack about 3W power Converter has implemented protection against opposite polarization of power supply and over voltage protection ESD 15kV on RS232 interface lines We pro...

Page 5: ...should be the upper part of the casing put hooks on the terminal and then press the bottom of the cover until you hear a characteristic Click sound 3 2 ETHERNET NETWORK CONNECTION The ADA 13110 has to...

Page 6: ...ernet connection will be describe in chapters below 3 2 1 CONNECTING TO NETWORK ADAPTER OF PC If there is not the switch or the HUB it is possible to connect the ADA 13110 directly to a network adapte...

Page 7: ...hub to operating in the Real Port mode 7 ADA 13110 ETHERNET Straight Cable Table 1 Local network ETHERNET built on the switch Device with RS232 interface RS232 PC with a network adapter Static IP addr...

Page 8: ...LAN connection to operating in the TCP UDP serial bridge mode one to one 8 ADA 13110 INTERNET ROUTER Public IP address RS232 ROUTER Public IP address ETHERNET Straight Cable Table 1 Device with RS232...

Page 9: ...built on the switch SLAVE device with RS232 interface ADA 13110 Static IP address ETHERNET Straight Cable Table 1 ADA 13110 Static IP address ADA 13110 Static IP address ETHERNET Straight Cable Table...

Page 10: ...se LEDs are respectively LED Description RS232 interface Power PWR Signalization of power supply RX Signalization of data receiving by ADA 13110 converter from RS232 TX Signalization of data transmiss...

Page 11: ...the list Devices and press Configure IP Settings in windows Set IP Address select option Automatically obtain network settings via DHCP default setting or Manually configure network setting In case of...

Page 12: ...network devices by the use Internet browser For configuration open the Internet Browser and type the address http ip converter address admin administration htm The login windows will open Enter User...

Page 13: ...l port of ADA 13110 converter includes port description setting of port profile operating mode and setting of serial transmission parameters baud rate data bits parity stop bits Select on left panel C...

Page 14: ...sage 5 2 2 1 2 TCP SOCKETS CONFIGURATION Choosing TCP Sockets is configured the serial port of ADA 13110 for direct communication with PC or other network device by the use of TCP socked Data sending...

Page 15: ...rt service is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client...

Page 16: ...en section UDP Server Settings with operating parameters like on picture below Set access to UDP server on e g 2101 port Then select Automatically send serial data in section UDP Client Settings this...

Page 17: ...In field Description enter e g location of the converter and MASTER device Send To enter IP address of converter connected to MASTER device UDP Port enter the number of port on which is working UDP S...

Page 18: ...rt service is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client...

Page 19: ...are to sections Serial Ports Connections 5 2 5 1 SERIAL PORTS MANAGEMENT Section Serial Ports allows to identification connections disconnection to the serial port of the converter through the network...

Page 20: ...m with ADANET_DRV 4 select catalog Drivers Windows Win XP 7 8 5 select file Setup exe for 32 bits system or Setup64 exe for 64 bits and press Open 6 when the installation window will appear press Next...

Page 21: ...Fig 20 Devices view on Windows XP Fig 21 Example configuration of multi port serial adapter 21 ADA 13110...

Page 22: ...loaded to the converter from the backup I changed the configuration and the converter isn t functioning 1 Enter in the Internet browser http converter ip address 2 Select the menu Factory Default Sett...

Page 23: ...port DSR red LED incoming signal on RS232 port DCD red LED incoming signal on RS232 port Electrical Parameters Power requirements 10 24 30 V DC Power Cable Recommended length up to 3m Power 3W Protect...

Page 24: ...mission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you present...

Reviews: