1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR

 Company product. This product has been completely tested and is covered by a two year 

warranty on parts and operation from date of sale.

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail support@cel-mar.pl.

1.1. GUARANTEE INFORMATION

ADA-4010A converter

 is covered by a two year warranty from date of sale. In case of being damaged it will be repair or the damaged

component   will   be   replace.   The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption   or   any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to 

CEL-MAR Company.

CEL-MAR Company

 under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases 

CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should install in the safe and stable place (e.g. switchbox unit), the powering cable should be arranged this way isn't

exposed to treading, catching or tear out from power circuit.

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete leaving out of the powering network is coming only after disconnecting voltage in the powering circuit.

Do not take the installation or device disassembly if it is turn on. It can lead to the electric short circuit and damaging the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity   is   available   by  contact   with   Technical   Service

(email: support@cel-mar.pl; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND CONSERVATION

The ADA-4010A converter doesn't require the periodic conservation.

Technical support at the number: +48 41 362-12-46 in 8.00-16.00, from Monday to Friday.

1.6. PACK CONTENTS

The converter is delivered with the user manual, resistors: Rt=120

W

 (2 pcs.), CD with ADAConfig software.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Possibility for adding the address to not addressable device connected to RS232 interface,

Conversion data format and baud rate on RS485 / RS422 and RS232 converter ports,

Operating on 2 or 4 wire bus in point-to-point or multi-point mode,

Conversion of TX, RX signals to RS485/RS422 standard,

RTS data flow control via RS232 port,

Operating up to 32 devices on RS485 network,

Baud rate of RS232 and RS485/422 interfaces (bps): 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 

38400, 57600, 76800, 115200, 230400,

RS232 & RS485/422 interface's data format: Number of data bites: 5, 6, 7, 8; Parity: None, Odd, Even; Number of stop bits : 1, 2,

Transparent for all protocols which data format is in accordance with the above specifications of RS485/422 interfaces e.g. 

MODBUS, DNP, PROFIBUS and others,

Power supply 10 - 30 VDC stable min. 2W,

5kV= optoisolation in signal channel between RS232 and RS485/RS422 interface,

1kV= or 3kV= galvanic isolation between RS485/RS422 interface and power supply,

Connection RS485/RS422 and RS232 buses and power supply via screw terminal block 2.5 mm

2

,

Implemented short circuit protection and over-voltage protection on RS-485/RS-422 interface's lines,

Protection against power supply reverse connection,

3

ADA-4010A

Summary of Contents for ADA-4010A

Page 1: ...User Manual ADA 4010A Addressable RS 485 RS 422 to RS 232 Baud Rate Converter 1 io_ada 4010a_v4 02_en ADA 4010A Copyright 2001 2017 CEL MAR sp j...

Page 2: ...CONNECTION OF RS232 INTERFACE DEVICES 7 3 4 POWER SUPPLY CONNECTION 7 4 ACTIVATION 7 4 1 DESCRIPTION OF SIGNALLING LEDS 8 4 2 TROUBLESHOOTING 8 5 CONFIGURATION 8 5 1 CONVERTERS OPERATION MODE 8 5 2 CO...

Page 3: ...ring circuit Do not take the installation or device disassembly if it is turn on It can lead to the electric short circuit and damaging the device The device can not be used for applications that dete...

Page 4: ...port converter supports asynchronous baud rate up to 230 4 kbps through one or two pairs of twisted cable of RS485 422 interface ADA 4010A is equipped with screw terminal block for connection of RS232...

Page 5: ...n TS 35 DIN35 rail To install the converter should be mounted on the rail upper part of the cover then press bottom part to hear characteristic Click sound 3 2 COMPUTER CONNECTION ADA 4010A can be con...

Page 6: ...ection of ADA 4010A to RS485 4W 4 wire bus and galvanic separation SLAVE device 6 ADA 4010A 5 GND GND 2 Rx 3 Tx RS232 connector DB 9F DCE Screw connector RS485 RS422 RS485 4W bus 9600Bd 8 O 1 RS232 co...

Page 7: ...Connections of SLAVE device with RS232 interface to ADA 4040A are shown on fig 5 fig 6 3 4 POWER SUPPLY CONNECTION To connect power supply to the converter should have DC power supplies regulated outp...

Page 8: ...e use a small flat screwdriver All available adjusting the SW1 switch are shown in table below Operation modes SW1 1 SW1 2 Mode OFF OFF Run ON OFF Configuration OFF ON Factory default Turning OFF and...

Page 9: ...S232 RS485 RS422 interfaces can be set a for RS232 interface signal DE Off disabled continuously signal DE Toggle RTS is setted ON during data transmission and OFF after end data transmission signal D...

Page 10: ...rrect message Fig 8 Selection of firmware file During loading software the yellow LED located beside SW1 micro switch will blink showing data flow to ADA 4010A If the software loaded correctly yellow...

Page 11: ...counters in the memory of the converter press Delete transmission errors In case of parity errors or frame errors should be checked the ADA 4010A converter s configuration and correctness connection...

Page 12: ...erefore converter can operate at full duplex mode on RS 422 and RS 485 RS2 4 wire bus Additionally can be set data flow control for RS485 RS422 and RS232 interfaces according to pt CONFIGURATION BY TH...

Page 13: ...Data Terminal Ready Looped with DSR GND SG Signal ground GND 9 VERSIONS ADA 4010A Order example Product Symbol ADA 4010A 23 3 23 3 way galvanic isolation 1kV 3 cover without inlets plug in screw term...

Page 14: ...d length of power cable up to 3m Power 2W Protection from reverse power polarization YES Galvanic Isolation 2 way or 3 way on the level 1kV or 3kV DC between power circuit and RS 485 422 signal line O...

Page 15: ...15 ADA 4010A...

Page 16: ...ransmission converters with interface RS232 RS485 RS422 USB Ethernet Wi Fi Current Loop Fibre Optic Converters and other Please contact us to tell how you like our products and how we can satisfy you...

Reviews: