Using ADA-4020 converters it is possible to create Current Loop bus as above.
In above example the current loop bus creates on converter ADA-4020-1-1-2-2-3 (MASTER – 

Active Transmitter

), one converter 

ADA-4020-1-1-2-2-3 (SLAVE - 

Active Transmitter

) furthest from the converter MASTER and max. 14 converters ADA-4020-1-1-2-2-3

(SLAVE – 

Passive Transmitter

). The number of SLAVE converters can be less for long lines.

3.6. POWER SUPPLY CONNECTION

The power supply to the ADA-4020 converter should be DC (regulated) from 10 V= to 30V=. Nominal power is typically 2W, e.g. ZS-

12/250, DR-15-24. Power cable from DC power supplies to device must not be longer than 3m. 

Observe the polarity, connect positive (+) of DC power supplies to V+ and negative (-) end to V- terminal. ADA-4020 has the protection

from opposite connection power supply. If after connection power supply on the front panel of the converter not light green LED PWR,

check correctness of power connection (polarization).

4. CONFIGURATION

The operating mode of ADA-4020 converter is set by the use of 6-positions SW1 switch. 

This switch is located near the screw terminal block (see Fig.1). To set the SW1 should be removed a terminal cover and using small, 

flat screwdriver make correct setting.

4.1. OPERATING MODE SETTING

All available operating modes are shows in table below. 

If there are any additional questions, please contact with technical support: suppor@cel-mar.pl or on the phone: +48 41 362-12-46.

Table 1. 

SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6

Description

Operating mode

OFF

OFF

OFF

OFF

OFF

OFF

RS-422 network

4-wire RS422 network. 

Full duplex or half duplex

transmission.

ON

ON

ON

ON

ON

ON

RS-485 network, automatic data flow

control

 2-wire and 4-wire RS485 network.

Full duplex or half duplex

transmission.

4.2. FACTORY DEFAULT

During production ADA-4020 converter is configured to operating in RS485 mode as in table below.

Table 2.

SW1-1 SW1-2 SW1-3 SW1-4 SW1-5

SW1-6

ON

ON

ON

ON

ON

ON

5. ACTIVATION

Converter can be powered after proper connection according to steps above. If the connection was made properly green LED PWR on

front  panel  of  converter  should  lit,  if  not check   polarization   of  power  connection.  If  the red  LED  RX is  lit check   correctness   of

connection transmitting line of Current Loop Device. The lighting of RX LED indicates no current flow through the optocoupler in the

receiver's circuit.
During proper data transmission through converter the LEDs Tx and Rx should blink.

LED

Description

PWR

Signalization of Power Supply

RX

Signalization of data receiving by ADA-4020 from Current Loop.

TX

Signalization of data transmission from ADA-4020 converter through Current Loop

10

ADA-4020

Summary of Contents for ADA-4020 Series

Page 1: ...User manual ADA 4020 RS 485 RS 422 to Current Loop converter 1 io_ada 4020_v3 20_en ADA 4020 Copyright 2001 2020 CEL MAR sp j...

Page 2: ...INSTALLATION 5 3 1 ASSEMBLING 5 3 2 CONNECTION TO RS232 COMPUTER PORT 5 3 3 CONNECTION TO RS485 422 BUS 6 3 3 1 CONNECTION TO RS485 4 WIRES BUS 6 3 3 2 CONNECTION TO RS485 2 WIRES BUS 7 3 3 3 EXTENDE...

Page 3: ...only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the device The devic...

Page 4: ...nsistor has also short circuit protection on TX and TX lines The transmitter of Current Loop 0 20mA can work as ACTIVE or Passive the selection is made by the TX switch on the front panel see Fig 1 Th...

Page 5: ...er powering use Interference suppression filters for power supply converters that are installed within a single object not power the converter from power circuit device that generates large impulse in...

Page 6: ...4020 to RS485 4W 4 wire network and galvanic separation of SLAVE device 6 ADA 4020 5 GND GND 2 Rx 3 Tx RS232 Connector DB 9F DCE RS485 422 Terminal block RS485 4W RS232 connector DB 9M DTE PC ADA I10...

Page 7: ...etwork Fig 7 Example connection of the ADA 4020 to RS485 2W 2 wire network and galvanic separation of SLAVE device 7 ADA 4020 5 GND GND 2 Rx 3 Tx RS232 connector DB 9F DCE Screw connector RS485 RS422...

Page 8: ...tor DB 9M DTE PC ADA I1040 GND 5 Tx 2 Rx 3 Rx Rx Tx A Tx B Tx A Tx B Rx Rx Rx Tx GND Rx Rx ADA 4020 Tx DATA A DATA B NC NC GND Tx A Tx B Rx Rx Rx Tx GND Rx Rx ADA 4020 Tx RS485 2W RS485 4W RS422 Tx A...

Page 9: ...ction of the ADA 4020 converters to Current Loop bus 9 ADA 4020 GND Current Loop Network MASTER RS485 Device Rt Rt Rx Rx Tx A Tx B RS485 2W SLAVE 2 RS485 SLAVE 15 RS485 Tx A Tx B Rx Rx RS485 RS422 con...

Page 10: ...ing 4 1 OPERATING MODE SETTING All available operating modes are shows in table below If there are any additional questions please contact with technical support suppor cel mar pl or on the phone 48 4...

Page 11: ...PECIFICATION TECHNICAL DATA Transmission Parameters Interface RS 485 RS 422 Current Loop Connector Screw terminal wire max 2 5mm2 Screw terminal wire max 2 5mm2 Line length up to 1200 m Depend on baud...

Page 12: ...40 Degree of terminal protection IP20 Weight 0 10 kg According to standards DIN EN50022 DIN EN43880 Location during work Free Mounting method On the rail compliant with DIN35 TS35 standard 12 ADA 4020...

Reviews: