8. VERSIONS
ADA-4020A -
-
-
-
Order example:
Product Symbol:
ADA-4020A-1-1-2-3
1
– Current Loop Voltage 24VDC,
1
– Current Loop Type ± 20mA,
2
– 1kV= galvanic isolation,
3
– cover without inlets, plug-in screw
terminal block.
Current Loop Voltage:
24VDC
1
12VDC
2
Current Loop Type:
± 20mA
1
0 - 20mA
2
Galvanic isolation:
1kV=, 3-way
2
3kV=, 3-way
3
Terminal & Terminal Cover:
Cover without inlets, screw terminal block
1
Cover with inlets, screw terminal block
2
Cover without inlets, plug-in screw terminal block
3
9. SPECIFICATION
TECHNICAL DATA
Transmission Parameters
Interface
RS-485/RS-422
Current Loop
Connector
Screw terminal, wire max. Ø 2,5mm
2
Screw terminal, wire max. Ø 2,5mm
2
Line length
Up to 1200 m
Depends on baud rate up to a few
kilometres
Maximum number of connected device
Up to 32
1
Maximum baud rate
230,4 kbps
38,4 kbps
Transmission line
Twisted cable 1-pair or 2-pair , UTP
Nx2x0,5 (24AWG), shield inside large
interferences STP Nx2x0,5(24AWG).
2-pair twisted cable, UTP Nx2x0,5
(24AWG), shield inside large
interferences STP Nx2x0,5(24AWG).
Transmission type
Asynchronism full duplex, half duplex.
Standards
EIA-232, CCITT V.24, EIA-485, CCITT V.11
Optical signalisation
•
PWR – green LED power supply,
•
RX - red LED data receiving from Current Loop,
•
TX - yellow LED data transmission through Current Loop CLO.
Electrical Parameters
Power requirements
10 - 24 – 30 V DC
Power Cable
Recommended length of power cable – up to 3m
Power
2W
Protection from reverse power polarization
YES
Galvanic Isolation
1kV= or 3kV= DC between power circuit and RS485/422 and Current Loop signal
lines
Optoisolation
3kV= between signal line RS-485/422 and Current Loop
Electromagnetic compatibility
Resistance to disruptions according to the standard PN-EN 55024.
Emission of disruptions according to the standard PN-EN 55022.
Safety requiring
According to the PN-EN60950 norm.
Environment
Commercial and light industrial.
Environmental Parameters
Operating temperature
-30 ÷ 60°C
Humidity
5 ÷ 95% - non-condensing
Storage temperature
-40 ÷ 70 °C
Casing
13
ADA-4020A
Summary of Contents for ADA-4020A
Page 15: ...15 ADA 4020A...