2.3. ISOLATION

Converter   ADA-4040PC1   has   3-way   galvanic   isolation   on   the   levels   1kV=   or   3kV=,   depend   on   version   described   in   section

VERSIONS.

Fig 2. Isolation structure

3. INSTALLATION

This chapter will show how to use and connect ADA-4040PC1 to RS485, RS422 network and power supply.

In the purpose of minimization of disruptions from environment is being recommended to:

- apply multipair type shielded cables, which shield can be connected to the earthing on one end of the cable,

- arrange signal cables in the distance not shorter than 25 cm from powering cables.

- apply cable of adequate cross-section due to voltage drops for converter powering,

- use suppression filters for powering converters that are installed within a single object.

- not supply converter from power circuit device that generates large impulse interference such as transmitters, contactors.

3.1. ASSEMBLING

The cover of ADA-4040PC1 converter is adapted to assembly on TS-35 (DIN35) rail. To install the converter, should be mounted on

the rail upper part of the cover then press bottom part to hear characteristic „Click” sound.

3.2. COMPUTER CONNECTION

To connect ADA-4040PC1 to computer equipped with RS-232 or USB interface, is needed additional converter e.g. ADA-I1040 RS232

to RS485/RS422 converter or ADA-I9140 USB to RS485/RS422 converter; connected to ASCII port of ADA-4040PC1.

Typical connections of ADA- 4040PC1 to PC are shown bellow. 

Fig 3. 4-Wires connection of ADA-4040PC1 to PC with the use of ADA-I1040 - RS232 to RS485/RS422 converter

Fig 4. 4-Wire connecting ADA-4040PC1 to PC with the use of ADA-I9140 USB to RS485/RS422

5

ADA-4040PC1

(5) GND

GND

(2) Rx

(3) Tx

RS232

Connector

DB-9F/DCE

RS485 / RS422

connector

RS232 

connector

DB-9M/DTE

PC

ADA-I1040

GND (5)

Tx (2)

Rx (3)

Rx+

Rx-

Tx+/ A

Tx-/ B

Tx+ / A

Tx- / B

   

Rx+

Rx-

RTU

RS485 / RS422

connector

Tx+ / A

Tx- / B

GND

Rx+

Rx-

ASCII

RS485 / RS422

connector

ADA-4040PC1

GND

GND

USB

USB

connector

RS485 / RS422

connector

USB

connector

ADA-I9140

USB

Rx+

Rx-

Tx+/ A

Tx-/ B

Tx+ / A

Tx- / B

   

Rx+

Rx-

RTU

RS485 / RS422

connector

Tx+ / A

Tx- / B

GND

Rx+

Rx-

ASCII

RS485 / RS422

connector

GND

PC

ADA-4040PC1

POWER

10 - 30VDC

MODBUS-

ASCII

RS485/RS422

MODBUS-

RTU

RS485/RS422

3-WAY ISOLATION

Summary of Contents for ADA-4040PC1

Page 1: ...User manual ADA 4040PC1 MODBUS ASCII to MODBUS RTU converter 1 io_ada 4040pc1_v1 03_en ADA 4040PC1 Copyright 2001 2017 CEL MAR sp j...

Page 2: ...485 NETWORK CONNECTION 6 3 3 1 RS485 4W BUS CONNECTION 6 3 3 2 RS485 2W BUS CONNECTION 7 3 3 3 GND TERMINALS CONNECTION 7 3 3 4 LINE TERMINATION Rt 7 3 3 5 SLAVE DEVICE CONNECTION 7 3 4 POWER SUPPLY C...

Page 3: ...twork is only after disconnecting the power supply circuit voltage Do not carry out the assembly or disassembly of the device if it is enabled This may result to short circuit and damage the device Th...

Page 4: ...on RS422 485 bus and increases its reliability ADA 4040PC supports the asynchronous baud rate up to 230 4 kbps through four or two pairs of twisted pair cables connected to screw terminals The convert...

Page 5: ...nverter should be mounted on the rail upper part of the cover then press bottom part to hear characteristic Click sound 3 2 COMPUTER CONNECTION To connect ADA 4040PC1 to computer equipped with RS 232...

Page 6: ...separation of SLAVE device 6 ADA 4040PC1 GND USB PC USB Rx Rx Tx A Tx B Tx A Tx B Rx Rx Tx A Tx B GND Rx Rx GND ADA I9140 ADA 4040PC1 USB connector RS485 RS422 connector USB connector RTU RS485 RS422...

Page 7: ...of SLAVE devices to ADA 4040PC1 are shown on fig 5 and fig 6 3 4 POWER SUPPLY CONNECTION To connect power supply to the converter should have DC power supplies regulated output voltage from 10 V to 30...

Page 8: ...n modes SW1 1 SW1 2 Mode OFF OFF Run ON OFF Configuration OFF ON Factory default Turning OFF and ON the power of the converter the configuration will be set to factory default ON ON Emergency firmware...

Page 9: ...d New Firmware to change the software delivered by manufacturer The Select File window will open fig below and select the bin file then click Open software will be load to ADAConfig buffer storage and...

Page 10: ...After microswitch setting should be restarted ADA 4040PC1 by turning OFF and then ON the power supply The yellow LED will light continuously and the converter will be in Emergency Firmware Update mod...

Page 11: ...n case of misrepresent bytes in transmitted sign This counter will not work in case of disable control parity To check those counters press the button Read transmission errors and to delete zeroing of...

Page 12: ...ds on baud rate Max number of connected device Up to 32 devices Baud rates bps 300 600 1200 1800 2400 4800 7200 9600 14400 19200 28800 38400 57600 76800 115200 230400 Data formats Data bits 5 6 7 8 Pa...

Page 13: ...5 RS 422 ASCII and RS 485 RS 422 RTU Electromagnetic compatibility Resistance to disruptions according to the standard PN EN 55024 Emission of disruptions according to the standard PN EN 55022 Safety...

Page 14: ...14 ADA 4040PC1...

Page 15: ...15 ADA 4040PC1...

Page 16: ...data transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy y...

Reviews: