Address
3X
Registers
Address
Registers
description
Attribute
Value
30020
19
VTG | COURSE REFERENCE: 309.62,
T
, ,
M
,
VTG | COURSE REFERENCE WORD: 0x544D
BYTE HI = 0x54 = 84 (ASCII – T ) - TRUE NORTH
BYTE LO = 0x4D = 77 (ASCII – M ) - MAGNETIC NORTH
R
16-bit register
CH[2]
30021
20
VTG | KNOTS:
0.131
,N,
VTG | KNOTS DWORD = 131 = 0x00 00 00 83
WORD LO = 0x0083; BYTE HI = 0x00; BYTE LO = 0x83
R
16-bit register
U32 LO
DW=1000
30022
21
VTG | KNOTS DWORD = 131 = 0x00 00 00 83
WORD HI = 0x0000; BYTE HI = 0x00; BYTE LO = 0x00
R
16-bit register
U32 HI
DW=1000
30023
22
VTG | KM:
0.212
,K
VTG | KM DWORD = 212 = 0x00 00 00 D4
WORD LO = 0x00D4; BYTE HI = 0x00; BYTE LO = 0xD4
R
16-bit register
U32 LO
DW=1000
30024
23
VTG | KM DWORD = 212 = 0x00 00 00 D4
WORD HI = 0x0000; BYTE HI = 0x00; BYTE LO = 0x00
R
16-bit register
U32 HI
DW=1000
30025
24
VTG | SPEED UNIT: 0.131,
N
,0.212,
K
VTG | SPEED UNIT WORD = 0x554B
BYTE HI = 0x4E = 78 (ASCII – N) - KNOTS
BYTE LO = 0x4B = 75 (ASCII – K) - KM
R
16-bit register
U16
30026
25
VTG | GPS STATUS INDICATOR:
A
BYTE HI = GPS STATUSHI = 0x00 = 00
BYTE LO = GPS STATUSLO = 0x41 = 65 (ASCII – A ) - GPS STATUS
A = Autonomous mode
D = Differential mode
E = Estimated (dead reckoning) mode
M = Manual input mode
S = Simulator mode
N = Data not valid
The positioning system Mode Indicator shall not be a null field
R
16-bit register
CH[2]
30027
26
VBW
VBW | LONGITUDINAL WATER SPEED: -998.1,
VBW | LONGITUDINAL WATER SPEED
WORD: -9981 = 0xD903
BYTE HI = 0xD9, BYTE LO = 0x03
R
16-bit register
I16
DW=10
30028
27
VBW | TRANSVERSE WATER SPEED: 1000.2,
VBW | TRANSVERSE WATER SPEED
WORD: 10002 = 0x2712
BYTE HI = 0x27, BYTE LO = 0x12
R
16-bit register
I16
DW=10
30029
28
VBW | LONGITUDINAL GROUND SPEED: -978.2,
VBW | LONGITUDINAL GROUND SPEED WORD = -9782 = 0xD9CA
BYTE HI = 0xD9, BYTE LO = 0xCA
R
16-bit register
I16
DW=10
30030
29
VBW | TRANSVERSE GROUND SPEED: 1000.0,
VBW | TRANSVERSE GROUND SPEED
WORD: 10000 = 0x2710
BYTE HI = 0x27, BYTE LO = 0x10
R
16-bit register
I16
DW=10
30031
30
VBW | STATUS, WATER / GROUND SPEED: AA
VBW | STATUS, WATER / GROUND SPEED WORD = 0x4141
BYTE HI = 0x41 = A (ASCII) STATUS, WATER SPEED
BYTE LO = 0x41 = A (ASCII) STATUS, GROUND SPEED
A = VALID DATA , V = INVALID DATA
R
16-bit register
U16
CH[2]
30032
31
VBW | STERN TRANSVERSE WATER SPEED: -1000.0,
VBW | STERN TRANSVERSE WATER SPEED
WORD: -10000= 0xD9CA
BYTE HI = 0xD9, BYTE LO = 0xCA
R
16-bit register
I16
DW=10
30033
32
VBW | STERN TRANSVERSE GROUND SPEED: 980.4
VBW | STERN TRANSVERSE GROUND SPEED
WORD: 9804 = 0x2710
BYTE HI = 0x27, BYTE LO = 0x10
R
16-bit register
I16
DW=10
30034
33
VBW | STATUS, STERN WATER/GROUND SPEED: AA
VBW | STATUS, STERN WATER/GROUND SPEED WORD = 0x4141
BYTE HI = 0x41 = A (ASCII) STATUS, WATER SPEED
BYTE LO = 0x41 = A (ASCII) STATUS, GROUND SPEED
A = VALID DATA, V = INVALID DATA
R
16-bit register
U16
CH[2]
30035
34
VLW
VLW | TOTAL CUMULATIVE WATER DISTANCE: 100007.048,N,
R
16-bit register
U32 LO
12
ADA-4040PC6
Summary of Contents for ADA-4040PC6