background image

1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION 

ADA-7020 converter

 is covered by a two year warranty from date of sale.  In case of being damaged it will be repair or the damaged

component   will   be   replace.   The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption   or   any
unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be
repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the CEL-MAR Company.

CEL-MAR Company

 under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases 

CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged so
as not to be exposed to trampling, attaching, or pulling out of the circuit. 
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 
Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.
The device can not be used for applications that determine human life and health (eg. Medical). 

ATTENTION!!! 
The device is equipped in the laser transmitter.
The radiation emitted by the laser transmitter is harmful to the eyes! 
Under no circumstances should never look to at the uncovered slot, to which it is not connected the fiber 
optic connector.

The manufacturer is not responsible for used not in accordance with the instruction manual. 
The user manual is an integral part of the device and with it is delivered to users.

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility Directive 

EMC 2014/30/WE.

 

Declaration of Conformity is delivered with purchased device.

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

ADA-7020 converter does not require the servicing and maintenance.
Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

support@cel-mar.pl

.

1.6. PACK CONTENTS

ADA-7020 converter; user manual; CE declaration.

2.  PRODUCT INFORMATION

2.1. PROPERTIES

Fibre-Optic to Current Loop conversion,

Operating on 4-wire bus of Current Loop standard,

Fibre-Optic connection via fore fibre connectors type: ST® * or SC – transmitter and receiver for an optical wavelength from 792nm
to 865 nm or SMA – transmitter and receiver for an optical wavelength from 640nm to 675nm.

Fibre Optic line: 2 mutimode optical fibres e.g. type 50/125 

m

m, 62,5/125 

m

m, 100/140 

m

m, 200 

m

m HCS, 1mm POF,

Transmission of RX, TX signals,

Baud rate up to 38,4 Kbps,

Transparent for all protocols: MODBUS, DNP, PROFIBUS and other,

Any format of byte referred to RS232 interface specification,

External power supply 10 – 30 VDC stable min. 2W,

1kV= or 3kV= galvanic isolation between Current Loop interface and power supply,

3

ADA-7020

Summary of Contents for ADA-7020

Page 1: ...User manual ADA 7020 Multimode Fibre Optic to Current Loop Converter 1 io_ada 7020_v3 19_en ADA 7020 Copyright 2001 2020 CEL MAR sp j...

Page 2: ...6 PACK CONTENTS 3 2 PRODUCT INFORMATION 3 2 1 PROPERTIES 3 2 2 DESCRIPTION 4 2 3 CURRENT LOOP TRANSMITTER 4 2 4 CURRENT LOOP RECEIVER 5 2 5 ISOLATION 5 3 INSTALLATION 5 3 1 ASSEMBLING 5 3 2 CONNECTION...

Page 3: ...disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circu...

Page 4: ...and one for RX signal The converter is equipped with screw terminal block for Current Loop and power connections To Current Loop bus built on the ADA 7020 can be connected two converters operating in...

Page 5: ...lded cables which shield can be connected to the earthing on one end of the cable arrange signal cables in the distance not shorter than 25 cm from powering cables apply cable of adequate cross sectio...

Page 6: ...m DC power supplies to device must not be longer than 3m Observe the polarity connect positive of DC power supplies to V and negative end to V screw terminal block ADA 7020 has the protection from opp...

Page 7: ...CATION TECHNICAL DATA PARAMETERS Interface Fibre Optic Current Loop Connector ST type transmitter and receiver for an optical wavelength from 792nm to 865nm SC type transmitter and receiver for an opt...

Page 8: ...ing Storage temperature 40 70 C Casing Dimensions 53 x 90 x 62mm Material ABS PC Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standards DIN EN50022 D...