background image

1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION 

ADA-7040 

converter is covered by a two year warranty from date of sale.

  

In case of being damaged it will be repair or the damaged

component   will   be   replace.   The   warranty   does   not   cover   damage   caused   from   improper   use,   materials   consumption   or   any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

ATTENTION!!! 
The device is equipped in the laser transmitter.
The radiation emitted by the laser transmitter is harmful to the eyes! 
Under no circumstances should never look to at the uncovered slot, to which it is not connected the fiber optic 
connector .

The manufacturer is not responsible for used not in accordance with the instruction manual. 
The user manual is an integral part of the device and with it is delivered to users.

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity   is   available   by  contact   with   Technical   Service

(email: support@cel-mar.pl; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

ADA-7040 converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

support@cel-mar.pl

.

1.6. PACK CONTENTS

The converter is delivered with the user manual and  resistors: Rt=120

W

 (2 pcs).

2.  PRODUCT INFORMATION

2.1. PROPERTIES

Fibre Optic to RS485 / RS422 conversion,

Fibre Optic connection via two fibre connectors type: ST® * or SC – transmitter and receiver for an optical wavelength from 792nm 

to 865 nm or SMA – transmitter and receiver for an optical wavelength from 640nm to 675nm.

Fibre Optic line: 2 mutimode optical fibres eg. type 50/125 

m

m, 62,5/125 

m

m, 100/140 

m

m, 200 

m

m HCS, 1mm POF,

Transmission of RX,TX signals,

Baud rate up to 500kbps,

Operating on RS-485 network 2 or 4 wire,

Automatic direction data flow control on RS485 network,

Transparent for all protocols: MODBUS, DNP, PROFIBUS and other,

3

ADA-7040

Summary of Contents for ADA-7040

Page 1: ...User manual ADA 7040 Multimode Fibre Optic to RS 485 RS 422 Converter 1 io_ada 7040_v3 24_en ADA 7040 Copyright 2001 2017 CEL MAR sp j...

Page 2: ...N 5 3 INSTALLATION 5 3 1 ASSEMBLING 5 3 2 CONNECTION TO RS485 RS422 NETWORK 5 3 2 1 CONNECTION TO 4 WIRE RS422 NETWORK 5 3 2 2 CONNECTION TO 4 WIRE RS485 NETWORK 6 3 2 3 CONNECTION TO 2 WIRE RS485 NET...

Page 3: ...and the like Complete disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may...

Page 4: ...d resistance to interference on the transmission bus The fibre connection is implemented by a line consisting of two fibres one fiber for the TX signal and one for RX signal Using two this type conver...

Page 5: ...converter from power circuit device that generates large impulse interference such as transmitters contactors 3 1 ASSEMBLING The ADA 7040 converter case is adapted to assembly on TS 35 DIN35 rail To i...

Page 6: ...3 4 5 Two resistors Rt 120W are supplied with ADA 7040 converter free of charge 3 3 CONNECTION FIBRE OPTIC BUS The multimode Fibre Optic with connectors type ST SC or SMA connect into their correspond...

Page 7: ...FF RS 422 bus 4 wire RS422 network Full duplex or half duplex transmission ON ON ON ON ON ON RS 485 bus automatic data flow control 2 wire and 4 wire RS485 network Full duplex or half duplex transmiss...

Page 8: ...mm optical power budget Tx Rx 9 6 dB up to 2500m for fibre type 62 5 125 mm optical power budget Tx Rx 15 dB up to 2000m for fibre type 100 140 mm optical power budget Tx Rx 15 dB up to 1500m for fib...

Page 9: ...d PN EN 55022 Safety requiring According to the PN EN60950 norm Environment Commercial and light industrial Environmental Parameters Operating temperature 30 C 60 C Humidity 5 95 non condensing Storag...

Page 10: ...10 ADA 7040...

Page 11: ...11 ADA 7040...

Page 12: ...transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you p...

Reviews: