background image

1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 

If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION 

The  

ADA-I911W  

converter is covered by a two year warranty from date of sale.   In case of being damaged it will be repair or the

damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company 

discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or disassembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical). 

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity  is   available   by   contact   with   Technical   Service

(email: support@cel-mar.pl; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

The ADA-I911W converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

support@cel-mar.pl

.

1.6. PACK CONTENTS

The converter is delivered with User Manual, USB Aw-Bw cable and drivers on CD-R

2. PRODUCT INFORMATION

2.1. PROPERTIES

USB to 1-WIRE conversion,

Signals: RX,TX,

Operating possibility on MicroLAN bus,

Programming possibility of EPROM memory on 1-WIRE bus (version 2-X),

Baud rate on 1-WIRE bus:  - standard up to 16,3 kbps, – overdrive up to 142 kbps,

Baud rate virtual COM port (on USB): 9600bps (standard), 19200bps, 57600bps, 115200bps supported by the 

DS9097U 

adapter,

Powering from USB port,

1 kV= or 3kV= (option) galvanic isolation between USB and 1-WIRE interfaces,

~3kV= optoisolation between USB and 1-WIRE interfaces on signal line,

USB interface connection via USB socked B-type,

1-WIRE bus connection via screw terminal block,

ABS material for casing,

Casing dimensions (L x H x D) 65mm x 50mm x 27mm,

3

ADA-I911W

Summary of Contents for ADA-I911W

Page 1: ...User manual ADA I911W USB to 1 WIRE converter 1 io_ada i911w_v en 1 01 ADA I911W Copyright 2001 2017 CEL MAR sp j...

Page 2: ...WIRE SENSORS CONNECTION 5 4 3 POWER SUPPLY 6 5 DRIVERS INSTALLATION IN SYSTEM WINDOWS 6 5 1 EXAMPLE DRIVER INSTALLATION IN WINDOWS 7 SYSTEM 6 6 DRIVER UNINSTALLATION 12 6 1 DRIVER UNINSTALLATION IN W...

Page 3: ...pt open or make holes in casings of the device Do not immerse device in water or no other liquid Do not put the fire opened on device sources candles an oil lamps and the like Complete disable from th...

Page 4: ...heating a remote control and monitoring of alarm systems fire extinguishers etc One of the fastest growing markets today is the market of alarm systems in which MicroLAN is used for connection the sen...

Page 5: ...nment on 1 WIRE bus it is recommended to use multipair type shielded cables which shield can be connected to the earthing on one end of the cable lay signal cables at a distance of not less than 25 cm...

Page 6: ...tion wizard will be installed the Drivers and Uninstaller for the Windows systems 98 ME 2000 XP 2003 Vista Win7 2008 Win8 d connect the convert to USB port of computer and follow the steps of installa...

Page 7: ...Press Next Select STANDARD Drivers and press Next 7 ADA I911W...

Page 8: ...Press Install Press Next will be installed Drivers for USB Bus 8 ADA I911W...

Page 9: ...Press Install this driver software anyway Installation of drivers for USB Bus will start 9 ADA I911W...

Page 10: ...Press Install this driver software anyway Installation of drivers for Virtual Port will start 10 ADA I911W...

Page 11: ...Press Finish Press Finish The driver for ADA I911W have been installed This can be checked in Uninstall or change a program 11 ADA I911W...

Page 12: ...ring installation was selected driver for Standard baud rates it is possible to use 9600 bps standard 19200 bps 57600 bps 115200 bps supported by the DS9097U adapter Selecting other baud rates will re...

Page 13: ...g press Change Remove driver converter of USB Bus will be uninstalled h after uninstallation reboot the computer 6 2 1 EXAMPLE DRIVER UNINSTALLATION IN WINDOWS 7 SYSTEMS Driver uninstallation in Windo...

Page 14: ...nstaller d from CDMUninstaller folder run the application uninstall bat e after finishing reboot the computer 7 USING After proper connection according to section above the converter can be used If co...

Page 15: ...terface TX yellow LED transmitted data via 1 WIRE interface Electrical Parameters Power requirements from USB of Computer Power Cable USB cable Power 1W Galvanic Isolation 1kV DC or 3kV DC between USB...

Page 16: ...ta transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you...

Reviews: