background image

Page 26 | 1-855-235-5271

CX

 040418

9.  The End User must first contact CellarCool Customer Service by telephone (at 1-800-343-9463) 

prior to attempting service on any Product still under the limited warranty; else the limited 

warranty is voided. 

10.  This limited warranty does not cover Product being concealed by, but not limited to, vegetation, 

fabric, shelving, mud, snow, or dirt. Product must not be painted or limited warranty will be void.

11.  This limited warranty does not cover exposure to corroding environments such as, but not limited 

to, petroleum and gasoline products, cleaning solvents, caustic pool chemicals, and marine air.

12.  This limited warranty does not cover any cause not relating to Product defect.
13.  THE REPAIR OR REPLACEMENT OF THE PRODUCT AS PROVIDED UNDER THIS LIMITED WARRANTY 

IS THE EXCLUSIVE REMEDY OF YOU, THE END USER, AS WELL AS ANYONE ELSE IN THE CHAIN OF 

TITLE OF THE PRODUCT, DOES NOT START A NEW LIMITED WARRANTY TIME PERIOD, AND IS IN LIEU 

OF ALL OTHER WARRANTIES (EXPRESS OR IMPLIED) WITH REGARD TO THE PRODUCT. IN NO EVENT 

SHALL CELLARCOOL BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT 

DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY 

EXPRESSLY DISCLAIMED.  Some states do not allow the exclusion or limitation of incidental or 

consequential damages, or allow limitations on how long an implied warranty lasts, so the above 

limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, 

and you may have other rights, which vary from state to state.

14.  Failure of the End User to comply with all of the Product Installation Requirements, Maintenance 

Requirements and End User Requirements may, at CellarCool’s sole discretion, void this limited 

warranty.

15.   No one has any authority to add to or vary the limited warranty on this Product.

3. Product Installation Requirements:

A. Prior to installing a CellarCool Product, the End User must read the CellarCool Owner’s Manual and 

thereafter the End User must follow the required installation, use and maintenance procedures set forth 

by CellarCool in CellarCool’s Owner’s Manual. The Owner’s Manual is shipped with each Product and 

if another copy is needed, replacement copies can be downloaded from CellarCool’s website (www.

cellarcool.com) or by contacting CellarCool directly for a new copy of the Owner’s Manual. 

B. It is highly recommended that the End User obtain the assistance of a wine storage professional.
C. Failing to address all of the variables associated with proper installation will cause the Product to operate 

incorrectly and limit both the Product’s ability to cool and the longevity of the Product itself.

D. The End User is responsible for all risks and costs of installation of the Product, including but not limited 

to all labor costs as well as cost of any additional parts required for the proper and complete installation 

of the Product.  The End User is responsible for all risks and costs of removing the Product if limited 

warranty work is required.

E.  The Product cannot operate at its optimum capacity if airflow is constricted by ducting or venting the 

exhaust side of the Product into a location with inadequate ventilation.

4. Maintenance Requirements

It is the End User’s responsibility to clean off any accumulated dust, lint, or other debris from the front and 

rear intake grills; failure to do this on a regular basis will restrict the airflow and may affect the Product’s 

ability to function properly. Periodically cleaning the Product’s vents will help assure maximum cooling 

efficiency.  The drain tube must also be checked and kept clean and free of debris and mold to maintain 

proper performance.
Mold is a natural living organism in the environment. It exists in the air in the form of microscopic spores 

that move in and out of buildings through doors, windows, vents, HVAC systems and anywhere else that 

air enters. Once it is discovered, mold must be addressed quickly and appropriately. Delayed or improper 

treatment of mold issues can result in costly and reoccurring repairs. If the End User suspects a mold 

problem, it is always best to hire a qualified and experienced mold remediation specialist.

Summary of Contents for cx2200

Page 1: ...CX SERIES OWNER S MANUAL cx2200 cx3300 cx4400 cx8800...

Page 2: ...not responsible for printing or clerical errors CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vi...

Page 3: ...tallation Airflow Control 9 Preparing the Installation Location 10 Preparing the Unit for Installation 11 Installing the System 11 Drain Line 13 System Operation 14 Controller Functions 15 Wiring Sche...

Page 4: ...ool cooling unit is a specialized refrigeration unit designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines It is...

Page 5: ...of the cellar over time by cycling cooler air throughout Test the unit prior to installation 5 You are required to install a drain line to remove condensation from the unit 6 The CellarCool unit is in...

Page 6: ...utlet Power surges and spikes can damage sensitive electrical equipment CellarCool recommends plugging the unit into a surge protector or power conditioner in order to protect your system As outlined...

Page 7: ...5 CX SERIES QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Power cord front location standard ON OFF switch for 4400 8800 models only Power cord rear location optional Air sensor Rear...

Page 8: ...s parts and labor 5 years compressor Sizing the Unit to the Room The specification chart will provide information on the unit s cooling capacity There are circumstances in which a cellar design may re...

Page 9: ...ly use CellarCool products It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months Standard fiberglass or rigi...

Page 10: ...rtion of the unit NOTE High humidity significantly increases the heat load on the cooling system Any break in the vapor barriers a cut a nail hole overlapping etc will cause a moisture leak and must b...

Page 11: ...will best suit your installation NOTE Do not cover both of the openings on the same side of the unit for any reason This will cause cooling issues and premature failure NOTE Do not cover both of the...

Page 12: ...rough your studs when you have a clear understanding what is inside the wall Now make the second horizontal cut from stud to stud on the line below the first cut Once the horizontal lines have been cu...

Page 13: ...ellar Note If you use decorative moulding it should be attached to the walls and never to the cooling unit itself The moulding itself should be removable incase the unit needs servicing Applying Insul...

Page 14: ...n each side of the side of the unit you will notice 6 indents these mark two different installation depths Select one of the two mounting depths and attach each mounting bracket to the unit with the s...

Page 15: ...s important that the drain line tube be properly connected and used to prevent leakage and other problems associated with excess condensation Failure to use the condensation drain line tube will void...

Page 16: ...has reached the setpoint to allow the pressure in the refrigeration unit to equalize prior to starting the compressor Anti Frost Cycle defrost After two hours of compressor operation the controller w...

Page 17: ...utton once more Use the UP and DOWN ARROW buttons in order to change the value until the desired setpoint is reached Hold the set button for approximately 5 seconds to enter the CPSM Customer Preferen...

Page 18: ...snowflake symbol will not be lit 2 Add heat to the room until the wine reaches the desired temperature Press and hold the SET button for approximately 5 seconds to enter the CPSM menu Use the DOWN AR...

Page 19: ...www cellarcool com Page 17 CX SERIES cx2200 cx3300 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 20: ...Page 18 1 855 235 5271 CX 040418 cx4400 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 21: ...www cellarcool com Page 19 CX SERIES cx8800 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 22: ...Page 20 1 855 235 5271 CX 040418 NOTES...

Page 23: ...ine voltage is incorrect rating for unit Check line voltage to make sure there is 110V 120V Room at setpoint Lower setpoint Thermostat not calling for cooling Lower setpoint Faulty thermostat or wirin...

Page 24: ...Solution Lack of airflow heat exhaust outer room Make sure fan is unobstructed clean evaporator if necessary The unit is undersized for the room Purchase correctly sized unit Evaporator fan runs but...

Page 25: ...USING INTERIOR DRAIN LINE Insert supplied drain line brush from this end Drop pan tab into drip tray through access door ACCESS DOOR CX2200 ACCESS DOOR CX3300 4400 8800 ACCESS DOOR SCREWS REAR OF UNIT...

Page 26: ...arCool Customer Service 1738 E Alpine Ave Stockton CA 95205 www cellarcool com Email support cellarcool com Tech Support Customer Service 1 800 343 9463 Sales Sizing Assistance 1 855 235 5271 Fax 209...

Page 27: ...d in the event the Product is not repairable in the field cover normal ground freight charges within the continental United States for the repair or replacement of the Product B Five 5 Year Compressor...

Page 28: ...arCool Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by CellarCool in CellarCool s Owner s Manual The Owner s Manual is ship...

Page 29: ...t 1738 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a...

Page 30: ...343 9463 or please send a letter via U S Mail to Customer Service CellarCool Corporation 1738 E Alpine Ave Stockton CA 95205 Email support cellarcool com Web www cellarcool com B Technical Assistance...

Page 31: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www cellarcool com...

Reviews: