QuickConnect Line Set
The Evaporator, Condensing Unit, Liquid Line and Insulated Suction Line (together the
Line Sets) are factory charged and shipped with R-134a refrigerant.
The components
must be installed together as a complete CellarPro system.
Do not substitute
components or use these components in a different split system. If any damage to the
components occurs that causes a loss of refrigerant, only a qualified HVACR service
technician certified to handle R-134a can perform the repairs.
Follow the installation instructions in sequence to ensure proper system
operation
:
1. Determine the final locations where the Evaporator and Condensing units will be
mounted, and verify that the QuickConnect Line Set has sufficient length to
interconnect the two units. If the line set is not long enough,
do not proceed.
Contact CellarPro for immediate assistance.
2. Reference the
Evaporator Mounting
and
Evaporator Connection
diagrams for
the model being installed. For rear connection configurations it is important to
properly locate the wall cutouts using the locating hole for the mounting bracket as
dimensioned on the diagrams. The diagrams also provide maximum outer
diameter dimensions for planning wall cutouts for side or bottom connection
configurations.
3. Make the connection cutout through the wall, and pull the Line Set through the
cutout into the cellar. If the drain line and/or power cord are configured out the
rear, feed these through the cutout from the evaporator to the outside of the cellar.
4. Locate the 4” tube insulation sleeve and long wire ties included in the parts kit.