5. Identify the insulated Suction line (marked BLUE on the female connector) and
slide the 4” tube insulation sleeve over the Suction line on the side where it will
connect to the evaporator.
6. Identify the male Suction line connection on the rear or optional left side of the
evaporator (marked BLUE on the male connector), and attach the female
Suction line connection to the male connection.
STOP AND
MAKE SURE
YOU ARE ATTACHING BLUE TO BLUE.
Hand thread at first to get the
threads started without cross threading. Once it is too hard to turn by hand,
use a crescent wrench until the connection stops tight - do not apply so much
force that the male connection starts to turn. Note that it is only necessary to
apply the wrench to the female connector, the male connector is locked in place
and should not be adjusted.
3000/4000Sqc Suction
Rear Connection
(Blue)
3000/4000Shqc Suction
Rear Connection
(Blue)